Targeted glucocorticoid analysis using ion mobility-mass spectrometry (IM-MS)
Open Access
- 6 April 2022
- journal article
- research article
- Published by Stanford University Press in Journal of Mass Spectrometry and Advances in the Clinical Lab
- Vol. 24, 50-56
Abstract
Ion mobility-mass spectrometry (IM-MS) is an emerging technique in the -omics fields that has broad potential applicability to the clinical lab. As a rapid, gas-phase structure-based separation technique, IM-MS offers promise in isomer separations and can be easily combined with existing LC-MS methods (i.e., LC-IM-MS). Several experimental conditions, including analyte cation adducts and drift composition further provide a means to tune separations for global and/or targeted applications. The primary objective of this study was to demonstrate the utility of IM-MS under a range of experimental conditions for detection of glucocorticoids, and specifically for the separation of several isomeric pairs. LC-IM-MS was used to characterize 16 glucocorticoids including three isomer pairs: cortisone/prednisolone, betamethasone/dexamethasone, and flunisolide/triamcinolone acetonide. Collision cross section (CCS) values were measured for all common adducts (e.g., protonated and sodiated) using both step-field and single-field methods. Alternative alkali, alkaline earth, and transition metals were introduced, such that their adducts could also be measured. Finally, four different drift gases (helium, nitrogen, argon, and carbon dioxide) were compared for their relative separation capability. LC-IM-MS offered a robust, multidimensional separation technique that allowed for the 16 glucocorticoids to be analyzed and separated in three-dimensions (retention time, CCS, and m/z). Despite the relatively modest resolution of isomer pairs under standard conditions (i.e., nitrogen drift gas, sodiated ions, etc.), improvements were observed for alkaline earth and transition metals (notable barium adducts) and in carbon dioxide drift gas. In summary, LC-IM-MS offers potential as a clinical method due to its ease of coupling with traditional LC-MS methods and its promise for tuning separations to better resolve targeted and/or global isomers in complex biological samples.Keywords
This publication has 35 references indexed in Scilit:
- Rapid Analysis of Anabolic Steroid Metabolites in Urine by Combining Field Asymmetric Waveform Ion Mobility Spectrometry with Liquid Chromatography and Mass SpectrometryAnalytical Chemistry, 2017
- Ion Mobility Collision Cross Section CompendiumAnalytical Chemistry, 2016
- Ion mobility-mass spectrometry separation of steroid structural isomers and epimersInternational Journal for Ion Mobility Spectrometry, 2016
- Experimental and Theoretical Investigation of Sodiated Multimers of Steroid Epimers with Ion Mobility-Mass SpectrometryJournal of the American Society for Mass Spectrometry, 2016
- Ion Mobility in Clinical Analysis: Current Progress and Future PerspectivesClinical Chemistry, 2016
- Complementing the characterization of in vivo generated N‐glucuronic acid conjugates of stanozolol by collision cross section computation and analysisDrug Testing and Analysis, 2015
- Evaluation of drift gas selection in complex sample analyses using a high performance drift tube ion mobility-QTOF mass spectrometerThe Analyst, 2015
- Ion Mobility-Mass Spectrometry: Time-Dispersive InstrumentationAnalytical Chemistry, 2014
- Separation of steroid isomers by ion mobility mass spectrometryJournal of Chromatography A, 2013
- Application of FAIMS to anabolic androgenic steroids in sport drug testingDrug Testing and Analysis, 2009