In-hospital follow-up of implantable cardioverter defibrillator and pacemaker carriers: patients' inconvenience and points of view. A four-hospital Italian survey
Authors:
Open Access
- 11 November 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 14 (3) , 345-350
Abstract
The increasing volume of pacemaker (PM) and implantable cardioverter defibrillator (ICD) implants and problems related to their functioning have highlighted the issue of device follow-ups. Patients' convenience regarding device visits has been little investigated. This work aims at surveying patients' efforts in attending the in-office PM/ICD follow-ups and at evaluating their expectations. In four Italian referral centres, over a 3-month period, a 20-point questionnaire was completed by all consecutive patients at in-hospital PM/ICD visits. In total, 1109 questionnaire/patients were evaluated. Pacemakers were 68%, ICDs 16%, and cardiac resynchronizations (CRTs) (PM + ICD) 16%; 38% were females; mean age was 75 ± 11 years. Almost all were scheduled visits. There was frequent reprogramming and clinical examination, even after 6 months from implant. Perceived inconvenience for the in-office follow-up was relevant in 35% of cases; attitudes towards remote monitoring were positive in 88% of cases. Inter-group analysis showed some significant difference: PM patients were older and more frequently female; ICD carriers were younger, had the highest rate of clinical evaluation, a longer journey time, and the most positive opinion about remote follow-up. Cardiac resynchronization patients had a longer waiting time and the lowest inconvenience. Overall inconvenience was independently predicted by increasing age, lengthy travelling times, and being accompanied; favourable opinions about remote monitoring were predicted by overall inconvenience, and, in ICD carriers only, by lack of clinical examination. Patients' perceptions of in-hospital PM/ICD visits were affected by age and by journey modalities. Individual factors seem to affect both opinions about in-office visits and expectations towards a possible remote follow-up.Keywords
This publication has 13 references indexed in Scilit:
- Efficacy and Safety of Automatic Remote Monitoring for Implantable Cardioverter-Defibrillator Follow-UpCirculation, 2010
- Long-term patient acceptance of and satisfaction with implanted device remote monitoringEP Europace, 2010
- Clinical Benefits of Remote Versus Transtelephonic Monitoring of Implanted PacemakersJACC, 2009
- Remote monitoring of implantable cardioverter defibrillator patients: a safe, time-saving, and cost-effective means for follow-upEP Europace, 2008
- Automatic home monitoring of implantable cardioverter defibrillatorsEP Europace, 2008
- HRS/EHRA Expert Consensus on the Monitoring of Cardiovascular Implantable Electronic Devices (CIEDs): Description of Techniques, Indications, Personnel, Frequency and Ethical ConsiderationsDeveloped in partnership with the Heart Rhythm Society (HRS) and the European Heart Rhythm Association (EHRA); and in collaboration with the American College of Cardiology (ACC), the American Heart Association (AHA), the European Society of Cardiology (ESC), the Heart Failure Association of ESC (HFA), and the Heart Failure Society of America (HFSA). Endorsed by the Heart Rhythm Society, the European Heart Rhythm Association (a registered branch of the ESC), the American College of Cardiology, the American Heart AssociationEP Europace, 2008
- Potential role of remote monitoring for scheduled and unscheduled evaluations of patients with an implantable defibrillatorEP Europace, 2008
- Practical Aspects of Implantable Defibrillator Therapy in Patients with Congenital Heart DiseasePacing and Clinical Electrophysiology, 2008
- Home monitoring remote control of pacemaker and implantable cardioverter defibrillator patients in clinical practice: impact on medical management and health-care resource utilizationEP Europace, 2008
- Remote Monitoring of Implantable Cardioverter Defibrillators:Pacing and Clinical Electrophysiology, 2004