Abstract
Introduction: Nosocomial transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been a major feature of the COVID-19 pandemic. Evidence suggests patients can auto-emit aerosols containing viable viruses; these aerosols could be further propagated when patients undergo certain treatments, including continuous positive airway pressure (PAP) therapy. Our aim was to assess 1) the degree of viable virus propagated from PAP circuit mask leak and 2) the efficacy of a ventilated plastic canopy to mitigate virus propagation.Methods: Bacteriophage phiX174 (108 copies·mL−1) was nebulised into a custom PAP circuit. Mask leak was systematically varied at the mask interface. Plates containingEscherichia colihost quantified viable virus (viaplaque forming unit) settling on surfaces around the room. The efficacy of a low-cost ventilated headboard created from a tarpaulin hood and a high-efficiency particulate air (HEPA) filter was tested.Results: Mask leak was associated with virus contamination in a dose-dependent manner (χ2=58.24, df=4, p−1) was associated with virus counts equivalent to using PAP with a vented mask. The highest frequency of viruses was detected on surfaces 3·h−1eradicated all evidence of virus contamination.Conclusions: Mask leak from PAP may be a major source of environmental contamination and nosocomial spread of infectious respiratory diseases. Subclinical mask leak levels should be treated as an infectious risk. Low-cost patient hoods with HEPA filtration are an effective countermeasure.Keywords
All Related Versions
This publication has 26 references indexed in Scilit:
- Aerosol Generating Procedures and Risk of Transmission of Acute Respiratory Infections to Healthcare Workers: A Systematic ReviewPLOS ONE, 2012
- Modality of human expired aerosol size distributionsJournal of Aerosol Science, 2011
- Risk Factors for SARS Transmission from Patients Requiring Intubation: A Multicentre Investigation in Toronto, CanadaPLOS ONE, 2010
- Exhaled Air Dispersion Distances During Noninvasive Ventilation via Different Respironics Face MasksChest, 2009
- Methods for Sampling of Airborne VirusesMicrobiology and Molecular Biology Reviews, 2008
- Noninvasive Positive-Pressure VentilationChest, 2006
- Transmission of Severe Acute Respiratory Syndrome during Intubation and Mechanical VentilationAmerican Journal of Respiratory and Critical Care Medicine, 2004
- Dispersal of Respiratory Droplets With Open vs Closed Oxygen Delivery MasksChest, 2004
- Superspreading SARS Events, Beijing, 2003Emerging Infectious Diseases, 2004
- Electron microscopic studies of bacteriophage φ X174 intact and ‘eclipsing’ particles, and the genome by the staining and shadowing methodJournal of Virological Methods, 1981