Synthesis of Patient-Specific Transmission Data for PET Attenuation Correction for PET/MRI Neuroimaging Using a Convolutional Neural Network
- 30 August 2018
- journal article
- research article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 60 (4) , 555-560
Abstract
Attenuation correction is a notable challenge associated with simultaneous PET/MRI, particularly in neuroimaging, where sharp boundaries between air and bone volumes exist. This leads to concerns regarding the visual and, more specifically, quantitative accuracy of PET reconstructions for data obtained with PET/MRI. Recently developed techniques can synthesize attenuation maps using only MRI data and are likely adequate for clinical use, however, little work has been conducted to assess their suitability for the dynamic PET studies frequently employed in research to derive physiological information such as binding potential of neuroreceptors in a region. At the same time, existing PET/MRI attenuation correction methods are predicated upon synthesizing CT data, which is not ideal, as CT data are acquired with much lower energy photons than PET data and thus do not optimally reflect the PET attenuation map. Methods: We trained a convolutional neural network to generate patient-specific transmission data from T1-weighted MRI. Using the trained network, we generated transmission data for a testing set comprising 11 subjects scanned with 11C-WAY-100635 and 10 subjects scanned with 11C-DASB. We assessed both static and dynamic reconstructions. For dynamic PET data, we report differences in BPND and BPF for 11C-WAY-100635 and VT for 11C-DASB. Results: The mean bias for generated transmission data was -1.06±0.81%. Global biases in static PET uptake were -0.49±1.7%, and -1.52±0.73% for 11C-WAY-100635 and 11C-DASB, respectively. Conclusion: Our neural network approach is capable of synthesizing patient-specific transmission data with sufficient accuracy for both static and dynamic PET studies.Keywords
This publication has 37 references indexed in Scilit:
- MRI for attenuation correction in PET: methods and challengesMagnetic Resonance Materials in Physics, Biology and Medicine, 2012
- Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR ScannerJournal of Nuclear Medicine, 2011
- Attenuation Correction Methods Suitable for Brain Imaging with a PET/MRI Scanner: A Comparison of Tissue Atlas and Template Attenuation Map ApproachesJournal of Nuclear Medicine, 2011
- Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical boneJournal of Magnetic Resonance, 2010
- In VivoQuantification of Human Serotonin 1A Receptor Using11C-CUMI-101, an Agonist PET RadiotracerJournal of Nuclear Medicine, 2010
- Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain PrototypeJournal of Nuclear Medicine, 2010
- In vivo Quantification of Serotonin Transporters Using [11C]DASB and Positron Emission Tomography in Humans: Modeling ConsiderationsJournal of Cerebral Blood Flow & Metabolism, 2007
- Estimation of kinetic parameters in graphical analysis of PET imaging dataStatistics in Medicine, 2003
- Fast robust automated brain extractionHuman Brain Mapping, 2002
- Double high-dose chemotherapy with autologous peripheral stem cell rescue in relapsed Wilms’ tumorBone Marrow Transplantation, 1997