Revision total hip arthroplasty using a fluted, tapered, modular stem follow-up method for a mean of three years: A preliminary study
Authors:
Open Access
- 23 May 2023
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 14, 873584
Abstract
Objective: This study aimed to evaluate the results and complications related to revision total hip arthroplasty within a short-to-medium follow up period.Methods: From January 2016 to January 2020, we reviewed 31 prosthetic hip arthroplasty stem revisions using a fluted, tapered modular stem with distal fixation. The median age of the patients was 74.55–79 years. The survival rate was 100%, and there were no re-revisions. The Harris hip score improved from an average of 36.5 ± 7.8 before surgery to 81.8 ± 6.2 at the final follow-up.Results: The average final follow-up was 36 (24–60) months. During this time, there was no periprosthetic infection, no prosthesis loosening or breakage, and no sciatic nerve injury. Complications included four (12.9%) intraoperative fractures and eight (25.8%) dislocations that had no stem fractures. The postoperative limb was lengthened by 17.8 ± 9.8 mm. In most cases, bone regeneration was an early and important finding. Three cases underwent extended trochanteric osteotomy, and bone healing was achieved by the final follow-up.Conclusion: The modular tapered stem reviewed in this study was very versatile, could be used in most femoral revision cases, and allowed for rapid bone reconstruction. However, a long-term follow-up study is needed to confirm these results.Keywords
This publication has 31 references indexed in Scilit:
- Management of Femoral Bone Loss in Revision Total Hip ArthroplastyHIP International, 2015
- Revision Total Hip Arthroplasty With Modular Femoral StemsThe Journal of Arthroplasty, 2014
- Component Selection in Revision Total Hip ArthroplastyOrthopedic Clinics of North America, 2014
- Managing femoral bone loss in revision total hip replacementThe Bone & Joint Journal, 2013
- Revision Total Hip Arthroplasty Using a Modular Femoral Implant in Paprosky Type III and IV Femoral Bone LossThe Journal of Arthroplasty, 2012
- Modular Femoral Stems for Revision Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2011
- The Use of Tapered Stems for Femoral Revision SurgeryClinical Orthopaedics and Related Research, 2004
- The Wagner revision prosthesis consistently restores femoral bone structureInternational Orthopaedics, 2000
- "Modes of Failure" of Cemented Stem-type Femoral ComponentsClinical Orthopaedics and Related Research, 1979
- MEASUREMENT OF PAINThe Lancet, 1974