Abstract
This study presents a novel approach for incipient fault detection in dynamical systems which is based on a two-step fuzzy/Bayesian formulation for change point detection in time series. The first step consists of a fuzzy-based clusterisation to transform the initial data, with arbitrary distribution, into a new one that can be approximated with a beta distribution. The second step consists in using the Metropolis–Hastings algorithm to the change point detection in the transformed time series. The incipient fault is detected as long as it characterises a change point in such transformed time series. The problem of incipient fault detection in the RTN DAMADICS is analysed.Keywords
This publication has 58 references indexed in Scilit:
- Observer-based strategies for actuator fault detection, isolation and estimation for certain class of uncertain nonlinear systemsIET Control Theory & Applications, 2007
- Parity relations for linear uncertain dynamic systemsAutomatica, 2006
- Passive robust fault detection using interval observers: Application to the DAMADICS benchmark problemControl Engineering Practice, 2006
- A review of process fault detection and diagnosisComputers & Chemical Engineering, 2003
- A review of process fault detection and diagnosisComputers & Chemical Engineering, 2003
- A review of process fault detection and diagnosisComputers & Chemical Engineering, 2003
- Unknown input observers for uncertain systems: a unifying approach and enhancements2002
- Fault Diagnosis of Non-Linear Dynamic Systems1999
- Discrete-time singular observers: H2/Hinfinity optimality and unknown inputsInternational Journal of Control, 1999
- Trends in the application of model-based fault detection and diagnosis of technical processesControl Engineering Practice, 1997