ASIC for High Rate 3D Position Sensitive Detectors
Authors:
- 14 June 2010
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 57 (3) , 1536-1542
Abstract
We report on the development of an application specific integrated circuit (ASIC) for 3D position sensitive detectors (3D PSD). The ASIC is designed to operate with pixelated wide bandgap sensors like Cadmium-Zinc-Telluride (CZT), Mercuric Iodide (Hgl2) and Thallium Bromide (TIBr). It measures the amplitudes and timings associated with an ionizing event on 128 anodes, the anode grid, and the cathode. Each channel provides low-noise charge amplification, high-order shaping with peaking time adjustable from 250 ns to 12 μs, gain adjustable to 20 mV/fC or 120 mV/fC (for a dynamic range of 3.2 MeV and 530 keV in CZT), amplitude discrimination with 5-bit trimming, and positive and negative peak and timing detections. The readout can be full or sparse, based on a flag and single- or multi-cycle token passing. All channels, triggered channels only, or triggered with neighbors can be read out thus increasing the rate capability of the system to more than 10 kcps. The ASIC dissipates 330 mW which corresponds to about 2.5 mW per channel.Keywords
This publication has 22 references indexed in Scilit:
- Energy resolution limiting factors of multi-pixel events in 3D position sensitive CZT gamma-ray spectrometer2008
- Detecting shielded sources using 3-D CdZnTe detectors2008
- Investigation of pixelated TlBr gamma-ray spectrometers with the depth-sensing techniqueNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2008
- Calibration strategy for 3-D position sensitive CdZnTe spectrometer arrays2007
- Pixellated TlBr detectors with the depth sensing techniqueNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- Maximum likelihood estimation maximization deconvolution in spatial and combined spatial- energy domains for a detector array system2007
- Recent Progress in TlBr Radiation Detectors2006
- Improved resolution for 3-D position sensitive CdZnTe spectrometersIEEE Transactions on Nuclear Science, 2004
- A modeling method to calibrate the interaction depth in 3-D position sensitive CdZnTe gamma-ray spectrometersIEEE Transactions on Nuclear Science, 2000
- 3-D position sensitive CdZnTe gamma-ray spectrometersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999