Most tall buildings use glass as its façade and exterior materials, which makes the building’s envelope is exposed to heat penetration. It is important to select and design the proportion between transparent and opaque materials for building façade to reduce the heat gain from outside, which is strategic to conserve the energy use for tall buildings. This study is aimed to observe the use of building façade materials in accordance with the strategic effort to reduce the heat gain in order to conserve the energy for AC system. The façade design modification is calculated by using Overall Thermal Transfer Value (OTTV) method in compliance with the Indonesia’s National Standard of Energy Conservation for Tall Buildings. The results show that the modification on façade design can reduce the heat gain and improve thermal performance of the building. There is a dramatic change of OTTV from 124.40 w/m2 on original design to 27.73 w/m2 after several steps of façade modification. The biggest reductions of OTTV is obtained when modifications on openings are applied. Since the heat transmission is mainly coming into buildings through openings, modifications on glass and windows are the keys. The change of glass material, from clear-glass to those with lower shading coefficient (SC) gives reduction of 37.52 w/m2.Keywords
This publication has 16 references indexed in Scilit:
- Investigating the environmental effectiveness of Overall Thermal Transfer Value code and its implication to energy regulation developmentEnergy Policy, 2019
- Re-designing facade of kadin tower building (application of retrofit programme with OTTV)IOP Conference Series: Materials Science and Engineering, 2019
- Comparative Study of Energy Consumption between OTTV and Sefaira in a HouseIOP Conference Series: Earth and Environmental Science, 2019
- Computational BIM for Building Envelope Sustainability OptimizationMATEC Web of Conferences, 2019
- An approach to calculate the equivalent solar heat gain coefficient of glass windows with fixed and dynamic shading in tropical climatesJournal of Building Engineering, 2019
- Simplification and adjustment of the energy consumption indices of office building envelopes in response to climate changeApplied Energy, 2018
- Optimizing the evaluation of building envelope design for thermal performance using a BIM-based overall thermal transfer value calculationBuilding and Environment, 2018
- The rising energy efficiency of office buildings in Hong KongEnergy and Buildings, 2018
- OTTV (SNI 03-6389-2011) and ETTV (BCA 2008) Calculation for Various Building’s Shapes, Orientations, Envelope Building Materials: Comparison and AnalysisCivil Engineering Dimension, 2015
- A review on the prediction of building energy consumptionRenewable and Sustainable Energy Reviews, 2012