Validity and clinical significance of biomechanical testing of implant/bone interface
Authors:
- 1 September 2006
- journal article
- review article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 17 (S2) , 2-7
Abstract
Purpose: The aim of this paper was to review the clinical literature on the Resonance frequency analysis (RFA) and Periotest techniques in order to assess the validity and prognostic value of each technique to detect implants at risk for failure.Material and methods: A search was made using the PubMed database to find clinical studies using the RFA and/or Periotest techniques.Results: A limited number of clinical reports were found. No randomized‐controlled clinical trials or prospective cohort studies could be found for validity testing of the techniques. Consequently, only a narrative review was prepared to cover general aspects of the techniques, factors influencing measurements and the clinical relevance of the techniques.Conclusions: Factors such as bone density, upper or lower jaw, abutment length and supracrestal implant length seem to influence both RFA and Periotest measurements. Data suggest that high RFA and low Periotest values indicate successfully integrated implants and that low/decreasing RFA and high/increasing Periotest values may be signs of ongoing disintegration and/or marginal bone loss. However, single readings using any of the techniques are of limited clinical value. The prognostic value of the RFA and Periotest techniques in predicting loss of implant stability has yet to be established in prospective clinical studies.Keywords
This publication has 38 references indexed in Scilit:
- Bone density and primary stability in implant therapyClinical Oral Implants Research, 2006
- Monitoring of implant stability in grafted bone using resonance frequency analysisA clinical study from implant placement to 6 months of loadingInternational Journal of Oral and Maxillofacial Surgery, 2005
- Early bone formation adjacent to rough and turned endosseous implant surfacesClinical Oral Implants Research, 2004
- Stability of the Bone‐Implant Complex. Results of Longitudinal Testing to 60 Months With the Periotest Device on Endosseous Dental ImplantsAnnals of Periodontology, 2000
- A comparison between cutting torque and resonance frequency measurements of maxillary implantsInternational Journal of Oral and Maxillofacial Surgery, 1999
- Stability measurements of one-stage Brånemark implants during healing in mandiblesInternational Journal of Oral and Maxillofacial Surgery, 1999
- Damping characteristics of bone‐to‐implant interface; A clinical study with the Periotest® device.Clinical Oral Implants Research, 1995
- In Vitro Consistency of the Periotest InstrumentJournal of Prosthodontics, 1993
- AN EVALUATION OF THE PERIOTEST SYSTEM. PART IImplant Dentistry, 1992
- AN EVALUATION OF THE PERIOTEST SYSTEM. PART II: RELIABILITY AND REPEATABILITY OF INSTRUMENTSImplant Dentistry, 1992