Potential of temperature-response collagen-genipin sols as a novel submucosal injection material for endoscopic resection
Authors:
Open Access
- 15 March 2019
- journal article
- research article
- Published by Georg Thieme Verlag KG in Endoscopy International Open
- Vol. 07 (04) , E561-E567
Abstract
Background and study aims We developed a novel submucosal (SM) injection material that contained pepsin-solubilized collagen (PSC), genipin (Ge) and phosphate buffer (PB). The aim of this study was to validate safety and usability of it for endoscopic resection (ER). Materials and methods In preliminary studies, 1) appropriate warming time and concentration of Ge, and concentration of NaCl in PB, 2) storage modulus of PSC, Ge, and PB mixture (PSC/Ge), and PSC as a mechanical property, 3) histological finding after injection, and histological toxicity of PSC/Ge was evaluated. We injected PSC/Ge, PSC, sodium hyaluronate (SH), dextrose (DW), and normal saline (NS) into SM of resected porcine stomach. We compared mean height of mucosal elevation after immediate injection (MH) and mean retaining rate at 60 minutes (MR) as ex vivo study. Results Optimal condition of PSC/Ge was Ge 5.5 mMol with 24 hours worming time and NaCl 280 mMol. PSC/Ge had better mechanical property than PSC. It was efficiently integrated and confined to the SM with acceptable toxicity. MH of PSC/Ge (5.1 ± 0.74 mm) and PSC (4.8 ± 0.84 mm) were significantly higher than NS (3.2 ± 0.84 mm). MR of PSC/Ge (100 ± 0.0%) was significantly higher than NS (61.7 ± 11.2%), DW (58.3 ± 11.8%) and SH (61.8 ± 8.6%). Conclusion PSC/Ge and PSC has potential to be safe and usable for ER. PSC/Ge was better than PSC because of better mechanical property than PSC.Keywords
This publication has 19 references indexed in Scilit:
- High pressure jet injection of viscous solutions for endoscopic submucosal dissection (ESD): first clinical experienceEndoscopy International Open, 2015
- A novel fabrication method to create a thick collagen bundle composed of uniaxially aligned fibrils: An essential technology for the development of artificial tendon/ligament matricesJournal of Biomedical Materials Research Part A, 2015
- Temperature-Responsive Gelation of Type I Collagen Solutions Involving Fibril Formation and Genipin Crosslinking as a Potential Injectable HydrogelInternational Journal of Biomaterials, 2013
- A pilot animal and clinical study of autologous blood solution compared with normal saline for use as an endoscopic submucosal cushionExperimental and Therapeutic Medicine, 2012
- Sodium alginate as an ideal submucosal injection material for endoscopic submucosal resection: preliminary experimental and clinical studyGastrointestinal Endoscopy, 2011
- CARBON DIOXIDE SUBMUCOSAL INJECTION CUSHION: AN INNOVATIVE TECHNIQUE IN ENDOSCOPIC SUBMUCOSAL DISSECTIONDigestive Endoscopy, 2010
- En bloc endoscopic submucosal dissection of a 14-cm laterally spreading adenoma of the rectum with involvement to the anal canal: expanding the frontiers of endoscopic surgery (with video)Gastrointestinal Endoscopy, 2008
- Genipin‐induced changes in collagen gels: Correlation of mechanical properties to fluorescenceJournal of Biomedical Materials Research Part A, 2008
- Comparison of Various Submucosal Injection Solutions for Maintaining Mucosal Elevation During Endoscopic Mucosal ResectionEndoscopy, 2004
- Endoscopic mucosal resectionGastrointestinal Endoscopy, 2003