A prospective evaluation of the contribution of ambient temperatures and transport times on infrared thermometry readings of intravenous fluids utilized in EMS patients
Open Access
- 16 December 2014
- journal article
- research article
- Published by Springer Nature in International Journal of Emergency Medicine
- Vol. 7 (1) , 47
Abstract
During cold weather months in much of the country, the temperatures in which prehospital care is delivered creates the potential for inadvertently cool intravenous fluids to be administered to patients during their transport and care by emergency medical services (EMS). There is some potential for patient harm from unintentional infusion of cool intravenous fluids. Prehospital providers in these cold weather environments are likely using fluids that are well below room temperature when prehospital intravenous fluid (IVF) warming techniques are not being employed. It was hypothesized that cold ambient temperatures during winter months in the study location would lead to the inadvertent infusion of cold intravenous fluids during prehospital patient care. Trained student research assistants obtained three sequential temperature measurements using an infrared thermometer in a convenience sample of intravenous fluid bags connected to patients arriving via EMS during two consecutive winter seasons (2011 to 2013) at our receiving hospital in Syracuse, New York. Intravenous fluids contained in anything other than a standard polyvinyl chloride bag were not measured and were not included in the study. Outdoor temperature was collected by referencing National Weather Service online data at the time of arrival. Official transport times from the scene to the emergency department (ED) and other demographic data was collected from the EMS provider or their patient care record at the time of EMS interaction. Twenty-three intravenous fluid bag temperatures were collected and analyzed. Outdoor temperature was significantly related to the temperature of the intravenous fluid being administered, b = 0.69, t(21) = 4.3, p < 0.001. Transport time did not predict the measured intravenous fluid temperatures, b = 0.12, t(20) = 0.55, p < 0.6. Use of unwarmed intravenous fluid in the prehospital environment during times of cold ambient temperatures can lead to the infusion of cool intravenous fluid and may result in harm to patients. Short transport times do not limit this risk. Emergency departments should not rely on EMS agencies’ use of intravenous fluid warming techniques and should consider replacing EMS intravenous fluids upon ED arrival to ensure patient safety.Keywords
This publication has 9 references indexed in Scilit:
- Three Insulation Methods to Minimize Intravenous Fluid Administration Set Heat LossPrehospital Emergency Care, 2012
- 124 Out-of-Hospital Warming of Intravenous Saline in an Austere EnvironmentAnnals of Emergency Medicine, 2011
- 74: Heat Loss From IV Fluids During the Administration of Pre-Warmed Normal SalineAnnals of Emergency Medicine, 2009
- Early Hypothermia in Severely Injured Trauma Patients Is a Significant Risk Factor for Multiple Organ Dysfunction Syndrome but Not MortalityAnnals of Surgery, 2009
- Hypothermia in the trauma patientInjury, 2004
- Is Hypothermia in the Victim of Major Trauma Protective or Harmful?Annals of Surgery, 1997
- Use of infrared thermometry to measure lavage and intravenous fluid temperatureThe American Journal of Emergency Medicine, 1995
- Advances in the Management of HypothermiaSurgical Clinics of North America, 1995
- Controlled trial of an intravenous fluid warmerAir Medical Journal, 1994