Usefulness of Controlled Aliasing in Parallel Imaging Results in Higher Acceleration in Gadoxetic Acid–Enhanced Liver Magnetic Resonance Imaging to Clarify the Hepatic Arterial Phase
Authors:
- Chang Hee LeeCLChang Hee Lee
- In Seong KimIKIn Seong Kim
- Berthold KieferBKBerthold Kiefer
- Seung Tae WooSWSeung Tae Woo
- Kyeong Ah KimKKKyeong Ah Kim
- Cheol Min ParkCPCheol Min Park
- 1 March 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 49 (3) , 183-188
Abstract
We aimed to determine whether the controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique could improve the image quality of the hepatic arterial phase of gadoxetic acid-enhanced liver magnetic resonance (MR) imaging. A total of 320 patients underwent gadoxetic acid-enhanced liver MR imaging: a conventional protocol (a fixed scan delay and 2-mL/s injection) using a standard 3-T MR system (Trio-Tim; Siemens, commercialized since 2005) (group A), an optimized protocol (bolus tracking and 1-mL/s injection) using a standard 3-T MR (group B), an optimized protocol using a new 3-T MR (Skyra; Siemens, commercialized since 2012) (group C), and an optimized protocol with CAIPIRINHA using a new 3-T MR (group D). The image quality of the hepatic arterial phase was graded using a 4-point rating scale from 1 (no artifacts) to 4 points (non-diagnostic images with severe artifacts). The differences in image quality scores among the 4 groups were evaluated. In addition, the detection rates of hypervascular hepatocellular carcinomas among the 4 groups were evaluated. Scores of 4 points were observed in groups A (n = 7), B (n = 5), and C (n = 3) but not in group D. The median image quality score was 2 in groups A and B and 1 in groups C and D. From group A to group D, the median image quality score decreased significantly (P = 0.0001). The median image quality score was significantly lower in group D than in groups A and B (P = 0.0001 and 0.001, respectively), whereas there was no significant difference observed between groups C and D (P = 0.656). The detection rates of hypervascular hepatocellular carcinomas on the hepatic arterial phase were not significantly different among the groups (all P > 0.03), except between groups A and D (P = 0.007). The CAIPIRINHA technique improved the image quality of hepatic arterial phase imaging with gadoxetic acid, reducing the number of non-diagnostic arterial phase studies.Keywords
This publication has 15 references indexed in Scilit:
- Comparison of Acute Transient Dyspnea after Intravenous Administration of Gadoxetate Disodium and Gadobenate Dimeglumine: Effect on Arterial Phase Image QualityRadiology, 2013
- Optimization of the dynamic, Gd-EOB-DTPA-enhanced MRI of the liver: the effect of the injection rateActa Radiologica, 2012
- Parallel MR imagingJournal of Magnetic Resonance Imaging, 2012
- Diagnostic Challenges and Pitfalls in MR Imaging with Hepatocyte-specific Contrast AgentsRadioGraphics, 2011
- Magnetic Resonance Imaging of the Liver: Sequence Optimization and ArtifactsMagnetic Resonance Imaging Clinics of North America, 2010
- Gadoxetate Disodium–Enhanced MRI of the Liver: Part 1, Protocol Optimization and Lesion Appearance in the Noncirrhotic LiverAmerican Journal of Roentgenology, 2010
- Gadoxetate Disodium–Enhanced MRI of the Liver: Part 2, Protocol Optimization and Lesion Appearance in the Cirrhotic LiverAmerican Journal of Roentgenology, 2010
- Gadoxetic Acid-Enhanced Magnetic Resonance Imaging for Differentiating Small Hepatocellular Carcinomas (≤2 cm in Diameter) From Arterial Enhancing PseudolesionsInvestigative Radiology, 2010
- Dilution method of gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd‐EOB‐DTPA)‐enhanced magnetic resonance imaging (MRI)Journal of Magnetic Resonance Imaging, 2009
- Parallel acquisition techniques for accelerated volumetric interpolated breath‐hold examination magnetic resonance imaging of the upper abdomen: Assessment of image quality and lesion conspicuityJournal of Magnetic Resonance Imaging, 2005