Radially expanding laparoscopic trocar ports significantly reduce postoperative pain in all age groups
- 13 October 2011
- journal article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 26 (3) , 843-846
Abstract
Trocar entry points have been identified as a significant source of pain after laparoscopic surgery. This is particularly true of the larger 12-mm ports that require deep fascial closure to avoid port-site herniation. We investigated whether using radially expanding trocars not requiring fascial closure compared to conventional cutting trocars for the 12-mm port in transabdominal preperitoneal (TAPP) hernia repairs had any effect on postoperative analgesic requirements and return to work or normal activity. The number of days analgesia was required postoperatively and the number of days taken to return to normal activity was recorded for 143 consecutive patients who underwent TAPP hernia repair by a single experienced laparoscopic surgeon. Exactly the same operative technique was used in these patients with the exception of the 12-mm port site entry. In group 1 (104 patients), a conventional cutting trocar was used requiring deep fascial closure. In group 2 (39 patients), a radially expanding trocar was used and the fascial defect was not closed. Analgesia was required for an average of 10.5 days in group 1 and 2.4 days in group 2 (P < 0.001). The average time to return to work or to normal activity was 23.4 days in group 1 and 15.6 days in group 2 (P = 0.004). There was no significant difference between the two groups with respect to the patients’ age, sex, or operating time. Using the laparoscopic TAPP hernia repair as a standardised operation, changing from 12-mm fascial port closure to a technique that uses port dilation (not requiring a potentially “tight” deeper fascial closure) in a similar group of patients shows that there is a significant reduction in postoperative analgesic requirement and an earlier return to productive work or normal lifestyle. Perhaps dilating ports should replace those larger 10-, 12-, and 15-mm ports that require deeper sutures in all laparoscopic surgical operations.Keywords
This publication has 16 references indexed in Scilit:
- Novel Methods of Closing 10-mm Laparoscopic Port-Site WoundsJournal of Laparoendoscopic & Advanced Surgical Techniques, 2009
- Randomized clinical trial comparing radially expanding trocars with conventional cutting trocars for the effects on pain after laparoscopic cholecystectomySurgical Endoscopy, 2007
- Randomized double-masked comparison of radially expanding access device and conventional cutting tip trocar in laparoscopyObstetrics & Gynecology, 2001
- Radially Expanding Trocar: A Less Painful Alternative for Laparoscopic SurgeryJournal of Laparoendoscopic & Advanced Surgical Techniques, 2000
- Entry force and intra-abdominal pressure associated with six laparoscopic trocar-cannula systems: a randomized comparisonObstetrics & Gynecology, 1999
- Laparoscopic Surgery Complications Associated with Trocar Tip Design: Review of Literature and Own ResultsJournal of Laparoendoscopic & Advanced Surgical Techniques, 1999
- A new, radially expanding access system for laparoscopic procedures versus conventional cannulasThe Journal of the American Association of Gynecologic Laparoscopists, 1996
- Radially expanding dilatationSurgical Endoscopy, 1996
- 149 ambulatory laparoscopic cholecystectomiesSurgical Endoscopy, 1996
- Incisional hernias after major laparoscopic gynecologic proceduresAmerican Journal of Obstetrics and Gynecology, 1993