Spinal anaesthesia for Caesarean section with bupivacaine 5 mg ml–1 in glucose 8 or 80 mg ml–1
Authors:
- G. A. McLeodGMG. A. McLeod
- J. A. W. WildsmithJWJ. A. W. Wildsmith
Open Access
- 1 June 2001
- journal article
- clinical trial
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 86 (6) , 805-807
Abstract
The standard spinal preparation of bupivacaine contains a high concentration of glucose (80 mg ml–1). However, the addition of only a small amount of glucose (8 mg ml–1) to plain solutions of bupivacaine results in a solution which, although no more than marginally hyperbaric, produces a more predictable block when used for spinal anaesthesia in non‐pregnant patients. However, bupivacaine 5 mg ml–1 in glucose 8 mg ml–1 has a density [1.00164 (sd 0.00008) at 37°C] which is relatively greater than that of the cerebrospinal fluid (CSF) of the pregnant patient at term (1.0003 at 37°C) because CSF density decreases during pregnancy. Therefore, a double‐blind, randomized, controlled study was carried out to compare intrathecal bupivacaine (glucose 8 mg ml–1) with bupivacaine (glucose 80 mg ml–1) in 40 pregnant patients at term. Although there was no difference between groups in onset of sensory block, dose of ephedrine or patient satisfaction, patients receiving bupivacaine (5 mg ml–1) with glucose (8 mg ml–1) had persistently higher sensory blocks between 60 and 120 min after intrathecal injection, suggesting that the spread of spinal solutions in the pregnant patient at term is not dependent on density. Br J Anaesth 2001; 86: 805–7Keywords
This publication has 9 references indexed in Scilit:
- Densities of cerebrospinal fluid and spinal anaesthetic solutions in surgical patients at body temperatureCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1998
- Intrathecal drug spreadCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1998
- Densities of Dextrose-Free Intrathecal Local Anesthetics, Opioids, and Combinations Measured at 37 degrees CAnesthesia & Analgesia, 1997
- Density of Lumbar Cerebrospinal Fluid in Pregnant and Nonpregnant HumansAnesthesiology, 1996
- Interaction between baricity (glucose concentration) and other factors influencing intrathecal drug spreadBritish Journal of Anaesthesia, 1994
- EFFECT OF GLUCOSE CONCENTRATION ON THE INTRATHECAL SPREAD OF 0.5% BUPIVACAINEBritish Journal of Anaesthesia, 1990
- EFFECT OF DEXTROSE CONCENTRATION ON THE INTRATHECAL SPREAD OF AMETHOCAINEBritish Journal of Anaesthesia, 1988
- SUBARACHNOID ANALGESIA FOR CAESAREAN SECTIONBritish Journal of Anaesthesia, 1987
- EFFECT OF BARICITY ON SPINAL ANAESTHESIA WITH BUPIVACAINEBritish Journal of Anaesthesia, 1981