Early results of a non-heartbeating donor (NHBD) programme with machine perfusion
Authors:
Open Access
- 1 June 2000
- journal article
- Published by Frontiers Media SA in Transplant International
- Vol. 13 (S1) , S255-S258
Abstract
Freeman Hospital, Newcastle upon Tyne restarted their non‐heartbeating donor (NHBD) programme in September 1998 using machine perfusion, due to early poor results with conventional cold storage (45% graft survival, phase II). Since then, 15 NHBD kidneys have been transplanted. The retrieval protocol consisted of in situ perfusion with a double balloon triple lumen cannula in Maastricht category II male donors age range 13‐59 years. Mean primary warm ischaemic time was 24.8 min (range 10‐44). All kidneys were machine perfused through a locally developed perfusion system. The viability was assessed by serial measurements of total GST (maximum acceptable limit of 200 units/l) and intrarenal vascular resistance (IRVR) was recorded. Fifteen of the 22 kidneys (68.62%) were transplanted. Delayed graft function (DGF) was seen in ten recipients (66.6%), two kidneys had immediate function (IF), one organ was exported, two recipients died of unrelated causes and a further seven kidneys were discarded (two had high tGST, two were infected and three had poor flow characteristics). In phase III, a success rate of 91.7% was thus achieved, which was better than the phase II period (P = 0.027, Fisher 2‐tail test). Machine perfusion has been successfully introduced in phase III to the Newcastle NHBD programme and facilitates viability assessment of NHBD kidneys.Keywords
This publication has 11 references indexed in Scilit:
- Comparison of the efficacy of University of Wisconsin solution and Newcastle organ perfusion fluid in the preservation of livers for transplantationTransplant International, 1998
- NATIONAL IMPACT OF PULSATILE PERFUSION ON CADAVERIC KIDNEY TRANSPLANTATION1Transplantation, 1997
- The non heart-beating donorBritish Medical Bulletin, 1997
- GLUTATHIONE S-TRANSFERASE AS PREDICTOR OF FUNCTIONAL OUTCOME IN TRANSPLANTATION OF MACHINE-PRESERVED NON-HEART-BEATING DONOR KIDNEYSTransplantation, 1997
- Glutathione transferase in the urine: A marker for post-transplant tubular lesionsKidney International, 1988
- ADVANTAGE OF COLD STORAGE OVER MACHINE PERFUSION FOR PRESERVATION OF CADAVER KIDNEYSTransplantation, 1982
- MACHINE-PERFUSED CADAVER KIDNEYSThe Lancet, 1975
- ASSESSMENT OF CADAVERIC KIDNEYS FOR TRANSPLANTATIONThe Lancet, 1974
- The effect of ischaemic injury on kidneys preserved for 24 hours before transplantationBritish Journal of Surgery, 1972
- Canine renal preservation following hypothermic perfusion and subsequent functionBritish Journal of Surgery, 1969