Identification of Alkyl Dimethylbenzylammonium Surfactants in Water Samples by Solid-Phase Extraction Followed by Ion Trap LC/MS and LC/MS/MS
- 19 May 2001
- journal article
- research article
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 35 (12) , 2583-2588
Abstract
A novel methodology was developed for the determination of alkyl (C12, C14, and C16) dimethylbenzylammonium chloride (benzalkonium chloride or BAC, Chemical Abstract Service number: 8001-54-5) in water samples. This method is based on solid-phase extraction (SPE) using polymeric cartridges, followed by high-performance liquid chromatography/ion trap mass spectrometry (LC/MS) and tandem mass spectrometry (MS/MS) detection, equipped with an electrospray interface in positive ion mode. Chromatographic separation was achieved for three BAC homologues by using a C18 column and a gradient of acetonitrile/10 millimolar aqueous ammonium formate. Total method recoveries were higher than 71% in different water matrices. The main ions observed by LC/MS were at mass-to-charge ratios (m/z) of 304, 332, and 360, which correspond to the molecular ions of the C12, C14, and C16 alkyl BAC, respectively. The unequivocal structural identification of these compounds in water samples was performed by LC/MS/MS after isolation and subsequent fragmentation of each molecular ion. The main fragmentation observed for the three different homologues corresponded to the loss of the toluyl group in the chemical structure, which leads to the fragment ions at m/z 212, 240, and 268 and a tropylium ion, characteristic of all homologues, at m/z 91. Detection limits for the methodology developed in this work were in the low nanogram-per-liter range. Concentration levels of BACranging from 1.2 to 36.6 micrograms per literwere found in surface-water samples collected downstream from different wastewater-treatment discharges, thus indicating its input and persistence through the wastewater-treatment process.Keywords
This publication has 6 references indexed in Scilit:
- Analysis of Cationic Surfactants by Microbore High-Performance Liquid Chromatography−Electrospray Mass SpectrometryAnalytical Chemistry, 1999
- Analysis of benzalkonium chloride in the effluent from European hospitals by solid-phase extraction and high-performance liquid chromatography with post-column ion-pairing and fluorescence detectionJournal of Chromatography A, 1997
- Determination of the Quaternary Ammonium Surfactant Ditallowdimethylammonium in Digested Sludges and Marine Sediments by Supercritical Fluid Extraction and Liquid Chromatography with Postcolumn Ion-Pair FormationAnalytical Chemistry, 1996
- Determination of benzalkonium chloride in eye care products by high-performance liquid chromatography and solid-phase extraction or on-line column switchingJournal of Chromatography A, 1992
- Analysis of benzalkonium chlorides by gas chromatographyJournal of Chromatography A, 1989
- Direct Determination of Benzalkonium Chloride in Ophthalmic Systems by Reversed-Phase High-Performance Liquid ChromatographyJournal of Pharmaceutical Sciences, 1987