Multiscale simulation of resist pattern shrinkage during scanning electron microscope observations
- 1 November 2015
- journal article
- research article
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 33 (6) , 06FH02
Abstract
Multiscale simulations were performed to study poly(methyl methacrylate) (PMMA) resist pattern shrinkage by electron irradiation. Shrinkage of the patterns, which ranged from several micrometers to sub-10 nm in initial size, was simulated. The decrease in film thickness of a several micrometers-thick PMMA resist during scanning electron microscope observations was evaluated by a Monte Carlo simulation of electron scattering. A simple molecular dynamics simulation was developed to analyze sub-10-nm-wide PMMA resist pattern shrinkage by electron irradiation. The shrinkage of several tens of nanometers-wide PMMA resist patterns was also simulated by combining molecular dynamics and Monte Carlo simulations.Keywords
Funding Information
- Japan Society for the Promotion of Science (15K13978)
- Japan Society for the Promotion of Science (25249052)
This publication has 19 references indexed in Scilit:
- Precise Cross-Sectional Measurement of Photoresist Shrinkage Caused by Electron Beam IrradiationJapanese Journal of Applied Physics, 2013
- Photoresist Shrinkage Caused by Single-Line Scan of Electron BeamJapanese Journal of Applied Physics, 2012
- Electron-beam induced photoresist shrinkage influence on 2D profiles2010
- Analytical model for ArF photoresist shrinkage under scanning electron microscopy inspectionJournal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena, 2009
- Phenomenology of electron-beam-induced photoresist shrinkage trends2009
- Study of Measurement Condition Optimization in Critical Dimension-Scanning Electron MicroscopeJapanese Journal of Applied Physics, 2008
- Characterization of E-beam induced resist slimming using etched feature measurements2005
- 193-nm CD shrinkage under SEM: modeling the mechanism2002
- Investigation on the mechanism of the 193-nm resist linewidth reduction during the SEM measurement2001
- CD changes of 193-nm resists during SEM measurement2001