Purpose: To evaluate diagnostic value of stress radiography and arthrometer measurements for anterior instability at different knee flexion angle positions. Methods: Forty‐three patients with complete anterior cruciate ligament (ACL) rupture (group 1) and 37 normal subjects (group 2) were enrolled prospectively. Arthrometer (KT‐1000) measurements and stress radiography by Telos were used to evaluate side‐to‐side differences. Results were recorded according to the knee position (30°, 45°, 60°, and 90°). Areas under the receiver operating characteristic curves (AUCs) were used to evaluate the diagnostic accuracy of each evaluation method. The calculated cutoff values at 30° position were used to evaluate the sensitivity and specificity of combined evaluation with stress radiography and arthrometer measurements. Results: The side‐to‐side differences on stress radiography and arthrometer measurements were significantly different between groups ( P < .05), except for the values at the 90° position in arthrometer measurements ( P = .844). The amount of anterior translation decreased in both arthrometer measurements and stress radiography between 30° and 45° positions ( P < .000); however, no further decrease was observed beyond 45°. The AUC of stress radiography at the 30° position was significantly higher than other values (AUC = 0.955; P = .000). Moreover, the clinical cutoff value of 3 mm showed 86.0% sensitivity and 89.2% specificity in stress radiography at 30°, which were higher than those in arthrometer measurements. Combined use of stress radiography and arthrometer measurements at the 30° position showed 100% sensitivity and 59.5% specificity as a screening test. Conclusions: Evaluation at the 30° knee position was significantly superior to that at other positions for both stress radiography and arthrometer measurements, whereas the 90° knee flexion position was not meaningful for any measurements. Evaluation needs to be performed with a 3‐mm cutoff value for stress radiography at the 30° knee position; however, combined use of stress radiography and arthrometer measurements at the 30° knee flexion can have a higher diagnostic value. Level of Evidence: Level I, diagnostic study of established criteria.Keywords
This publication has 40 references indexed in Scilit:
- Comparison of 5 Different Methods for Measuring Stress Radiographs to Improve Reproducibility During the Evaluation of Knee InstabilityThe American Journal of Sports Medicine, 2011
- Accuracy and Reliability of Anterior Cruciate Ligament Clinical Examination in a Multidisciplinary Sports Medicine SettingClinical Journal of Sport Medicine, 2010
- Correlation of Valgus Stress Radiographs with Medial Knee Ligament InjuriesThe American Journal of Sports Medicine, 2009
- In vivo kinematics of the ACL during weight‐bearing knee flexionJournal of Orthopaedic Research, 2005
- In Vivo Elongation of the Anterior Cruciate Ligament and Posterior Cruciate Ligament during Knee FlexionThe American Journal of Sports Medicine, 2004
- Combined knee loading states that generate high anterior cruciate ligament forcesJournal of Orthopaedic Research, 1995
- The accuracy of the clinical knee examination documented by arthroscopyThe American Journal of Sports Medicine, 1993
- Stressradiography of the kneeActa Orthopaedica, 1992
- Gonylaxometry: Stress Radiographic Measurement of Passive Stability in the Knee Joints of Normal Subjects and Patients with Ligament InjuriesActa Orthopaedica, 1981
- Stress Radiographical Measurement of the Anteroposterior, Medial and Lateral Stability of the Knee JointActa Orthopaedica, 1976