Four-Year Results of Summit Stems for Total Hip Arthroplasty in Japanese Patients
- 9 September 2015
- journal article
- Published by SAGE Publications in HIP International
- Vol. 25 (6) , 553-556
Abstract
Purpose: A retrospective study to evaluate the clinical and radiographic outcome of the Summit primary total hip arthroplasty (THA) at a minimum follow-up of 4 years. Methods: 87 hips in 84 Japanese patients underwent THA using Summit stems. 3 patients were lost to follow-up, and 4 patients were excluded because a Summit stem was judged to be inappropriate for their narrow femoral canals. The remaining 80 hips in 77 patients were evaluated. Mean age was 66 years (range, 33-86 y). Mean postoperative follow-up period was 52 months (range, 48-66 m). Results: There was no early stem subsidence after surgery. Of the 80 hips, 60 (75%) showed radiographic signs of stem osseointegration including zones 3 and 5 at final follow-up. Stress shielding occurred in 50 hips (62.5%), and third-degree stress shielding was observed in 12 hips (15%). 3 patients experienced postoperative thigh pain due to distal fixation. Conclusions: These short-term results indicate that the Summit stem achieved good initial fixation, although there were some cases of distal fixation. Careful long-term follow-up and observation will be necessary for hips in which stress shielding occurs.Keywords
This publication has 17 references indexed in Scilit:
- Five- to Ten-Year Outcomes for Modular Metal-On-Metal Total Hip ArthroplastyThe Journal of Arthroplasty, 2013
- Total hip arthroplasty using S-ROM prosthesis in elder patients with type C and B boneJournal of Orthopaedics, 2013
- Metal on Metal Total Hip Arthroplasty Using Modular Acetabular ShellsThe Journal of Arthroplasty, 2013
- Minimum 5-Year Results in 96 Consecutive Hips Treated With a Tapered Titanium Stem SystemThe Journal of Arthroplasty, 2010
- Five-Year Results of Metal-on-Metal Resurfacing Arthroplasty in Asian PatientsThe Journal of Arthroplasty, 2007
- Stem length and canal filling in uncemented custom-made total hip arthroplastyInternational Orthopaedics, 1999
- A Tapered Titanium Femoral Stem Inserted without Cement in a Total Hip Arthroplasty. Radiographic Evaluation and Stability*Journal of Bone and Joint Surgery, 1996
- Structural and cellular assessment of bone quality of proximal femurBone, 1993
- Uncemented porous-coated anatomic total hip replacement. Results at six years in a consecutive seriesThe Journal of Bone and Joint Surgery. British volume, 1993
- Traumatic Arthritis of the Hip after Dislocation and Acetabular FracturesJournal of Bone and Joint Surgery, 1969