Highly selective and sensitive determination of copper ion by two novel optical sensors
Authors:
- Mehrorang GhaediMGMehrorang Ghaedi
- Javad TashkhourianJTJavad Tashkhourian
- Morteza MontazerozohoriMMMorteza Montazerozohori
- Mahdi Nejati BiyarehMBMahdi Nejati Biyareh
- Batool SadeghianBSBatool Sadeghian
Open Access
- 1 May 2017
- journal article
- Published by Scientific Scholar in Arabian Journal of Chemistry
- Vol. 10, S2319-S2326
Abstract
New optical sensors for the determination of copper ion by incorporation of 1,1′-(4-nitro-1,2-phenylene)bis(azan-1-yl-1-ylidene)bis(methan-1-yl-1-lidene)dinaphthalen-2-ol(L1), 1,1′-2,2′-(1,2-phenylene)bis(ethene-2,1-diyl)dinaphthalen-2-ol 1(L2), dibutylphthalate (DBP) and sodium tetraphenylborate (Na-TPB) to the plasticized polyvinyl chloride matrices were prepared. The tendency of both ionophores (L2 and L1) as chromoionophore was significantly enhanced by the addition of DBP to the membrane. The proposed sensors benefit from advantages such as high stability, reproducibility and relatively long lifetime, good selectivity for Cu2+ ion determination over a large number of alkali, alkaline earth, transition and heavy metal ions. At optimum values of membrane compositions and experimental conditions, both sensors’ response was linear over a concentration range of 7.98×10−6 to 1.31×10−4molL−1 and 1.99×10−6 to 5.12×10−5molL−1 for L2 and L1, respectively. Sensor detection limit based on the definition that the concentration of the sample leads to a signal equal to the blank signal plus three times of its standard deviation was found to be 3.99×10−7 and 5.88×10−7molL−1 for L2 and L1, respectively. The response time of the optodes (defined as the time required reaching the 90% of the peak signal) was found to be 5–8min for L2 and 20–25min for L1 based sensor. The proposed optical sensors were applied successfully for the determination of Cu2+ ion content in water samplesKeywords
This publication has 25 references indexed in Scilit:
- Solid phase extraction of heavy metal ions in environmental samples on multiwalled carbon nanotubesJournal of Hazardous Materials, 2008
- An optical copper(II)-selective sensor based on a newly synthesized thioxanthone derivative, 1-hydroxy-3,4-dimethylthioxanthoneSensors and Actuators B: Chemical, 2006
- Design of a copper (II) optode based on immobilization of dithizone on a triacetylcellulose membraneSensors and Actuators B: Chemical, 2005
- Characterization of an optical copper sensor based on N,N′-bis(salycilidene)-1,2-phenylenediamineAnalytica Chimica Acta, 2005
- A highly versatile stable optical sensor based on 4-decyloxy-2-(2-pyridylazo)-1-naphthol in Nafion for the determination of copperSensors and Actuators B: Chemical, 2002
- SEPARATION AND ENRICHMENT OF CHROMIUM, COPPER, NICKEL AND LEAD IN SURFACE SEAWATER SAMPLES ON A COLUMN FILLED WITH AMBERLITE XAD-2000Analytical Letters, 2001
- An optical redox chemical sensor based on ferroin immobilised in a Nafion® membraneAnalytica Chimica Acta, 1999
- Optical pH Sensor Based On Chemical Modification of Polymer FilmMicrochemical Journal, 1999
- Nafion-based optode for the detection of metal ions in flow analysisAnalytica Chimica Acta, 1996
- Optical pH sensor based on the chemical modification of a porous polymer filmAnalytical Chemistry, 1988