Object-level response estimation for a collimated Geiger–Müller array under non-uniform contamination
Authors:
- Yongzhuo LiuYLYongzhuo Liu
- Jiangmei ZhangJZJiangmei Zhang
- Haolin LiuHLHaolin Liu
- Fayuan XiFXFayuan Xi
- Yongfa MiYMYongfa Mi
Preprint
- 10 October 2026
- preprint
- Published by Elsevier in SSRN Electronic Journal
Abstract
Estimating individual object contributions from a collimated radiation array is difficult when extended objects have overlapping projections and non-uniform internal emission. We develop a geometry-informed inverse measurement method for a Geiger–Müller (GM) array and assess contribution estimates and their uncertainty under simulated readout conditions. OpenGATE response matrices retain the full material geometry. Four nonnegative subregion coefficients per object are estimated with a finite-window nonparalyzable count likelihood and within-object shrinkage, then aggregated into expected net responses before dead-time losses. A null-space condition characterizes identifiability of these aggregates, and scene-level split conformal calibration provides contribution intervals. Evaluation uses 1440 main-test and 2040 controlled observations from 40 independent test geometries. At 500 reference net counts, mean contribution-fraction error is 0.2653, 13.4% below uniform-source likelihood estimation overall and 35.9% lower under localized contamination. The uniform model remains more accurate for uniform contamination. Sensitivity-scaled intervals are 21.1% narrower on average than fixed-width intervals and jointly cover all object contributions in 40/40 test scenes. As a derived discrimination measure, the intervals identify a unique leading object in 55/360 observations. Source partitioning improves quantification when localized emission causes uniform-template mismatch; geometric response coupling and small contribution gaps still limit discrimination. The results characterize estimation performance for parameterized GM readout rather than a physically calibrated detector array.Keywords
This publication has 17 references indexed in Scilit:
- GATE 10 Monte Carlo particle transport simulation: I. Development and new featuresPhysics in Medicine & Biology, 2026
- Reconstructing the Position and Intensity of Multiple Gamma-Ray Point Sources With a Sparse Parametric AlgorithmIEEE Transactions on Nuclear Science, 2020
- Gamma-Ray Point-Source Localization and Sparse Image Reconstruction Using Poisson LikelihoodIEEE Transactions on Nuclear Science, 2019
- Distribution-Free Predictive Inference for RegressionJournal of the American Statistical Association, 2018
- Scene data fusion: Real-time standoff volumetric gamma-ray imagingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- An improved method for the non-destructive characterization of radioactive waste by gamma scanningApplied Radiation and Isotopes, 2009
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Mean and variance of single photon counting with deadtimePhysics in Medicine & Biology, 2000
- Maximum Likelihood Reconstruction for Emission TomographyIEEE Transactions on Medical Imaging, 1982
- Dead-time problemsNuclear Instruments and Methods, 1973