Ambulatory Tonometric Blood Pressure Measurements in Patients with Diabetes
- 1 June 2012
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 14 (6) , 453-456
Abstract
Background: Arterial tonometry is a novel technique for measuring ambulatory blood pressure (AMBP). The watch-like device BPro® (HealthSTATS International, Singapore) captures radial pulsewave reflection and calculates brachial blood pressure (BP). In this study we investigate if arterial tonometry is applicable and reliable in patients with diabetes. Subjects and Methods: We compared tonometric (BPro) to cuff-based oscillometric and auscultatoric BPs (Takeda model TM2421, A&D Medical, Tokyo, Japan) in 25 Caucasian patients with type 1 or type 2 diabetes. Patients were seen twice within 2 weeks. At visit 1, a 15-min rest was followed by the recording of three cuff-based BPs and 2-min continuous tonometric BPs. At both visits 24-h AMBP measurements were recorded with the BPro device. Results: At Visit 1, auscultatoric BP (mean±SD) was 136±19/72±8 mm Hg versus 138±19/78±8 mm Hg with the tonometric device. Visit 1 AMBP was 131±20/76±9 mm Hg versus 131±12/75±9 mm Hg at Visit 2. Mean 24-h AMBP, daytime BP, nighttime BP, and dipping at the two visits were similar (P>0.40). Linear and intraclass correlations coefficients between auscultatoric and tonometric systolic and diastolic BP were r=0.86 and 0.65, respectively (Pr=0.83 and 0.77, respectively (PConclusions: In patients with diabetes tonometric and cuff-based BPs are comparable, and tonometric AMBPs are reproducible and feasible.Keywords
This publication has 10 references indexed in Scilit:
- Cardiovascular Outcomes in Framingham Participants With DiabetesHypertension, 2011
- Arterial stiffness and vascular complications in patients with type 1 diabetes: The Finnish Diabetic Nephropathy (FinnDiane) StudyAnnals of Medicine, 2010
- Standards of Medical Care in Diabetes—2010Diabetes Care, 2010
- The use of ambulatory tonometric radial arterial wave capture to measure ambulatory blood pressure: the validation of a novel wrist-bound device in adultsJournal of Human Hypertension, 2007
- Recommendations for Blood Pressure Measurement in Humans and Experimental AnimalsCirculation, 2005
- European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurementJournal Of Hypertension, 2003
- Aortic Stiffness Is an Independent Predictor of Primary Coronary Events in Hypertensive PatientsHypertension, 2002
- Arterial Stiffness as Underlying Mechanism of Disagreement Between an Oscillometric Blood Pressure Monitor and a SphygmomanometerHypertension, 2000
- Association of systolic blood pressure with macrovascular and microvascular complications of type 2 diabetes (UKPDS 36): prospective observational studyBMJ, 2000
- Estimation of Central Aortic Pressure Waveform by Mathematical Transformation of Radial Tonometry PressureCirculation, 1997