Treatment of distal tibial fractures by minimally invasive percutaneous plate osteosynthesis of three different plates: Results and cost-effectiveness analysis

Authors:
  • YTYuan Kun Tu
    Yuan Kun Tu

Abstract
Results Complete union was achieved in all patients. Good or excellent outcomes were achieved in 86% of the conventional plate cases and 79% of the LCP cases ( p = 0.716). The infection rate was 18% in the conventional plate group and 8% in the LCP group ( p = 0.430). The malalignment rates in the sagittal plane of the tibia were 7.1% and 8.3% in the conventional plate and LCP groups, respectively. The results showed no significant differences between treatment of distal tibia fractures with conventional plates or LCPs. Conclusion The use of conventional plates or LCPs provides a similar outcome in the treatment of distal tibial fractures. However, the LCP is more expensive than the conventional plate. This study showed that the surgical outcome of displaced distal tibial fractures is not affected by the use of LCP. Keywords buttress or dynamic compression plates distal tibial fractures locking compression plate 1 Introduction The management of displaced distal tibial fractures is a controversial and debatable topic. 1 The classic Arbeitsgemeinschaft für Osteosynthesefragen (AO, Association for the Study of Internal Fixation) technique of open anatomic reduction and internal fixation of distal tibial fractures requires extensive soft-tissue dissection and often leads to subsequent periosteal injury. High rates of complications, including postoperative infection, delayed union, and nonunion, have been reported. 2–6 However, the application of external fixators as the sole method for treating distal tibial fractures can lead to pin tract infections, loosening, and inadequate bone healing. 7,8 Indirect reduction and biologic percutaneous plating without direct manipulation of the fracture fragments result in good clinical outcomes. 9–12 The main goal of biologic plating techniques is to maintain the soft-tissue attachments and vascularity of the cortical bone fragments, 13,14 thereby theoretically reducing the risk of postoperative infection and nonunion. Conventional plates such as dynamic compression plates (DCPs) or buttress T plates have been inserted via minimally invasive methods for treating distal tibial fractures, with encouraging results. 10,15–19 Recently, some studies have reported the use of locking plates in treating fractures of the distal tibial shaft and metaphysis. Several studies have reported good clinical outcomes in distal tibial fractures treated with locking compression plates (LCPs) (Synthes, Paoli, PA, USA). 1,20,21 LCPs may provide greater stiffness in some situations. They may also maintain a better periosteal blood flow by minimizing the contact of the plate with bone; however, the implants may be more prominent. 22,23 LCPs are expensive and not covered under the Taiwan National Health Insurance program. It is questionable whether this more expensive implant provides any advantage over the conventional buttress or DCPs for treating distal tibial fractures. Therefore, we evaluated whether there were any clinical, radiologic, and cost-effectiveness differences between the use of conventional plates and LCPs for treating displaced distal tibial fractures. 2 Materials and methods This study is a retrospective review of the medical records in our teaching hospital. From July 2003 to February 2008, 57 consecutive patients were admitted to the E-Da hospital with distal metaphyseal tibial fractures. The surgical indication was that if the fracture fragments were displaced, surgery was performed by one surgeon. The exclusion criteria were as follows: nondisplaced fracture fragments; AO/Orthopaedic Trauma Association Type B and Type C3 fractures; open Type IIIb and IIIc fractures that required indirect reduction; and conditions in which biologic percutaneous plating could not be performed. Based on the above criteria, 52 consecutive patients (17 women and 35 men; mean age, 48.8 years) were evaluated in this study ( Table 1 ). We evaluated the clinical and radiologic findings of the 52 patients with displaced distal tibial fractures who underwent percutaneous plating with either conventional plates or LCPs. The implant was chosen by the patients themselves because the cost of the LCP was not covered under the National Health Insurance system. The conventional plate group comprised 28 patients with 28 fractures. The LCP group comprised 24 patients with 24 fractures. The preoperative radiographs of the 52 patients were retrospectively reviewed, and the fractures were classified according to the AO classification system ( Table 1 ). There were 6 Type A1, 8 Type A2, 18 Type A3, 5 Type C1, and 15 Type C2 fractures. Operations were performed within 24 hours of presentation and within 48 hours after injuries, except in patients with open Type II fractures with a large open wound and Type IIIa fractures. These patients were initially treated with debridement and Hoffman external skeletal fixation; 7–10 days later, they underwent percutaneous plating. 2.1 Operative technique Patients were placed supine on a radiolucent table, and fluoroscopic guidance was used for optimal diaphyseal–metaphyseal alignment, anatomic reduction of the joint surfaces, and implant fixation. A small rolled surgical towel, acting as a fulcrum, was placed in the concave area posterior to the Achilles tendon region. A 3.0-mm Kirschner wire (K-wire) was placed through the calcaneus at the extension line of the posterior tibial cortex with continuous manual traction. When treating an AO Type C (C1 or C2) fracture, the distal tibial fracture fragments were reduced by indirect reduction with traction and joystick manipulation with a 2.0-mm K-wire. Subsequently, the fracture fragments were stabilized using one or two 4.5-mm cannulated screws. Under fluoroscopic guidance, two 3- to 4-cm skin incisions were made on the medial side of the tibia at the proximal and distal parts of the estimated position of the plate. After the conventional plates (DCP or T plate) were inserted,...

This publication has 26 references indexed in Scilit: