REMOVAL OF OXYGEN FROM METHANE AND THE USE OF NUCLEAR SPIN RELAXATION TO MEASURE OXYGEN CONCENTRATION

Authors:
  • HSH. S. Sandhu
    H. S. Sandhu
  • JLJ. Lees
    J. Lees
  • MBM. Bloom
    M. Bloom

Abstract
Nuclear spin relaxation measurements are used to measure quantitatively the amount of oxygen present in methane. An upper limit of 2.5 × 10−4% is placed on the amount of oxygen present in methane after treatment with a getter made of misch metal.