Abstract
The replacement of an otosclerotic fixed stapes by a prosthesis significantly modifies the function of the normal ossicular chain. Because the ear works as a pressure receptor, a piston prosthesis will both modify the sound pressure transmission and respond to the ambient air pressure changes in a different way than the normal stapes. Both aspects, the acoustic transmission and the displacements of the prosthesis with variations of atmospheric pressures, are reviewed. The diameter of a piston should not be smaller than 0.4 mm and it should be inserted into a significantly larger perforation of the footplate. A low mass is advantageous for transmission of higher frequencies. Firm attachment at the processus lenticularis is necessary for effective energy transmission. This is of paramount importance in a malleovestibulopexy because of the oblique position of the piston. A piston can be displaced up to 0.5 mm in the vestibule at ambient air pressure changes, as it is not attached to the annular ligament. These large movements explain why a short piston can be lifted out of the footplate fenestration (i.e., after sneezing) and why a piston with excessive length can impale the structures of the membranous labyrinth, causing vertigo (i.e., in a retraction of the tympanic membrane). However, flying or diving should be allowed generally, provided that a test with tympanometry, applying variable pressures of +/- 400 mm H(2)O, is tolerated without evoking vertigo.Keywords
This publication has 36 references indexed in Scilit:
- Effect of Teflon Piston Diameter On Hearing Result After StapedotomyOtolaryngology–Head and Neck Surgery, 2001
- Zur Rekonstruktion des Schallleitungsapparates unter biomechanischen GesichtspunktenLaryngo-Rhino-Otologie, 2000
- Fortschritte in der StapeschirurgieLaryngo-Rhino-Otologie, 2000
- Stapedotomy Piston Diameter – Is Bigger Better?Oto-Rhino-Laryngologia Nova, 1999
- Stapedotomy: does prosthesis diameter affect outcome?Clinical Otolaryngology, 1999
- Middle ear mechanics in normal, diseased and reconstructed earsThe Journal of Laryngology & Otology, 1998
- A retrospective study of the hearing results obtained after stapedotomy by the implantation of two Teflon pistons with a different diameterEuropean Archives of Oto-Rhino-Laryngology, 1997
- Ergebnisse mit Goldpistons bei der Stapedektomie mit kleiner FensterungOto-Rhino-Laryngologia Nova, 1997
- Stapedotomy with Stapedius Tendon Preservation: Technique and Long‐Term ResultsOtolaryngology–Head and Neck Surgery, 1994
- Funktionelle Ergebnisse nach StapesplastikLaryngo-Rhino-Otologie, 1983