Wear of sequentially enhanced 9‐Mrad polyethylene in 10 million cycle knee simulation study
Authors:
- Paul Allen WilliamsPWPaul Allen Williams
- Mikiko TsukamotoMTMikiko Tsukamoto
- Ian C. ClarkeICIan C. Clarke
- 20 December 2007
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 86B (1) , 119-124
Abstract
Highly crosslinked polyethylene (HXPE) has been shown to be effective in reducing wear in total hip replacements. HXPE has not found widespread use in TKR, because the crosslinking inevitably leads to reductions in critical properties such as toughness and fatigue strength. Sequentially enhanced crosslinking (SXPE) have been suggested for improved wear resistance for tibial inserts with maintenance of mechanical properties and anticipated high oxidation resistance superior to conventional polyethylene (XLPE). We compared the wear of SXPE (9Mrad) to XLPE inserts (3Mrad) to 10 million cycles. Triathlon™ femoral condyles were identical in both. This is the first wear study of SXPE inserts. According to the power law relating irradiation dose to wear of XLPE inserts, wear of 9 Mrad inserts should be reduced by 70% compared to 3Mrad controls. The wear rates of the SXPE inserts were reduced by 86% at 10 million cycles duration, somewhat greater than predicted. The one prior investigation by the manufacturer reported a 79% wear reduction for SXPE compared to controls in a 5 million cycle simulator study in knee design and test parameters. There were important differences between the two studies. Nevertheless there clearly appeared to be a major benefit for sequentially enhanced polyethylene in tibial inserts. This combined wear reduction of 80‐85% with improved oxidation resistance and retention of mechanical properties may prove beneficial for active patients who may otherwise risk high wear rates over many years of use. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2008Keywords
This publication has 29 references indexed in Scilit:
- Wear and toughness of crosslinked polyethylene for total knee replacements: A study using a simulator and small‐punch testingJournal of Orthopaedic Research, 2006
- Osteolysis Associated with a Cemented tModular Posterior-Cruciate-Substituting Total Knee DesignJournal of Bone and Joint Surgery, 2002
- Wear of high-dose gamma-irradiated polyethylene in total hip replacementsJournal of Orthopaedic Science, 2000
- Development of an extremely wear‐resistant ultra high molecular weight polythylene for total hip replacementsJournal of Orthopaedic Research, 1999
- Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethyleneThe Journal of Bone and Joint Surgery. British volume, 1999
- Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacementsTribology International, 1998
- Post-irradiation aging of ultra-high molecular weight polyethylene.Journal of Bone and Joint Surgery, 1994
- The total condylar prosthesis. 10- to 12-year results of a cemented knee replacementThe Journal of Bone and Joint Surgery. British volume, 1989
- Survivorship of cemented knee replacementsThe Journal of Bone and Joint Surgery. British volume, 1989
- Effect of radiation sterilization and aging on ultrahigh molecular weight polyethyleneJournal of Biomedical Materials Research, 1981