Keratoconus Detection Based on a Single Scheimpflug Image
Open Access
- 3 June 2020
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 9 (7) , 36
Abstract
Purpose: To introduce a new approach for keratoconus detection based on corneal microstructure observed in vivo derived from a single Scheimpflug image. Methods: Scheimpflug single-image snapshots from 25 control subjects and 25 keratoconus eyes were analyzed; from each group, five subjects were randomly selected to provide out-of-sample data. Each corneal image was segmented, after which the stromal pixel intensities were statistically modeled with a Weibull distribution. Distribution estimated parameters α and β, characterizing corneal microstructure, were used in combination with a macrostructure parameter, central corneal thickness (CCT), for the detection of keratoconus. In addition, receiver operating characteristic curves were used to determine the sensitivity and specificity of each parameter for keratoconus detection. Results: The combination of CCT (sensitivity = 88%; specificity = 84%) with microscopic parameters extracted from statistical modeling of light intensity distribution, α (sensitivity = 76%; specificity = 76%) and β (sensitivity = 96%; specificity = 88%), from a single Scheimpflug image was found to be a successful tool to differentiate between keratoconus and control eyes with no misclassifications (sensitivity = 100%; specificity = 100%) with coefficients of variation up to 2.5%. Conclusions: The combination of microscopic and macroscopic corneal parameters extracted from a static Scheimpflug image is a promising, non-invasive tool to differentiate corneal diseases without the need to perform measurements based on induced deformation of the corneal structure. Translational Relevance: The proposed methodology has the potential to support clinicians in the detection of keratoconus, without compromising patient comfort.Keywords
This publication has 26 references indexed in Scilit:
- Biomechanical Characterization of Keratoconus Corneas Ex Vivo With Brillouin MicroscopyInvestigative Ophthalmology & Visual Science, 2014
- Biomechanical Responses of Healthy and Keratoconic Corneas Measured Using a Noncontact Scheimpflug-Based TonometerInvestigative Ophthalmology & Visual Science, 2014
- Corneal Biomechanical Assessment Using Corneal Visualization Scheimpflug Technology in Keratoconic and Normal EyesJournal of Ophthalmology, 2014
- The pathogenesis of keratoconusEye, 2013
- Evaluation of Scheimpflug imaging parameters in subclinical keratoconus, keratoconus, and normal eyesJournal of Cataract & Refractive Surgery, 2011
- Topographic and Tomographic Properties of Forme Fruste Keratoconus CorneasInvestigative Ophthalmology & Visual Science, 2010
- Biomechanical Properties of Keratoconus Suspect EyesInvestigative Ophthalmology & Visual Science, 2010
- Evaluation of Keratometric, Pachymetric, and Elevation Parameters of Keratoconic Corneas With PentacamCornea, 2009
- Changes in Collagen Orientation and Distribution in Keratoconus CorneasInvestigative Ophthalmology & Visual Science, 2005
- Epithelial and corneal thickness measurements by in vivo confocal microscopy through focusing (CMTF)Current Eye Research, 1997