Abstract
The self‐discharge kinetics were studied by means of cells equipped with a pressure sensor to determine the time‐dependence of cell pressure. The cell pressure variation was found to depend strongly upon cell state of charge (e.g., whether the nickel oxyhydroxide was of β‐ or γ‐type). For overcharged cells (e.g., having a mixture of β‐ and γ‐NiOOH as the nickel electrode) two different rate processes were observed for the self‐discharge rate as a function of time. For longer times the curve could be well fitted by assuming a single self‐discharge mechanism corresponding to the direct reduction of β(III)by hydrogen. In contrast, for shorter times the first part of the experimental curve exhibited a higher tangential slope, suggesting most likely a combination of two self‐discharge mechanisms, (i) the direct reduction of γ‐phase by hydrogen and (ii) electrochemical reduction involving the catalytic oxidation of hydrogen at the sintered matrix. © 1999 The Electrochemical Society. All rights reserved.