Countercurrent Chromatographic Separation of Proteins by Cross-Axis Coil Planet Centrifuge: Choice of Polymer Phase Systems and Revolution Speed
Authors:
- 1 June 1998
- journal article
- research article
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 21 (11) , 1727-1736
Abstract
Countercurrent chromatographic separation of proteins by the cross-axis coil planet centrifuge was maximized by selecting the suitable polymer phase system and revolution speed. Polymer phase systems composed of polyethylene glycol (PEG) 1000 and several inorganic salts were examined to determine partition coefficient values (K) for various proteins. The overall results indicated that the polymer phase system composed of 12.5% (w/w) PEG 1000 and 12.5% (w/w) dibasic potassium phosphate yielded suitable K values for most proteins except for cytochrome C and apo-transferrin which may be separable with a solvent system composed of 12.5% (w/w) PEG 1000 and 24% (w/w) potassium citrate. A series of experiments with the PEG 1000 - potassium phosphate system under various revolution speeds revealed that the best separation was achieved at 850 rpm. The above optimized conditions may be applied to separations of other protein samples.Keywords
This publication has 9 references indexed in Scilit:
- Protein Separation by Improved Cross-Axis Coil Planet Centrifuge with Eccentric Coil AssembliesJournal of Liquid Chromatography & Related Technologies, 1996
- Countercurrent chromatographic analysis of ovalbumin obtained from various sources using the cross-axis coil planet centrifugeJournal of Chromatography A, 1996
- Studies on a new cross-axis coil planet centrifuge for performing counter-current chromatographyJournal of Chromatography A, 1993
- Countercurrent Chromatography of Proteins with Polyethylene Glycol-Dextran Polymer Phase Systems Using Type-XLLL Cross-Axis Coil Planet CentrifugeJournal of Liquid Chromatography, 1992
- Cross-axis synchronous flow-through coil planet centrifuge (type XLL)Journal of Chromatography A, 1991
- Protein separation with aqueous—aqueous polymer systems by two types of counter-current chromatographsJournal of Chromatography A, 1991
- Improved cross-axis synchronous flow-through coil planet centrifuge for performing counter-current chromatography : I. Design of the apparatus and analysis of accelarationJournal of Chromatography A, 1989
- Cross-Axis Synchronous Flow-Through Coil Planet Centrifuge Free of Rotary Seals for Preparative Countercurrent Chromatography. Part II. Studies on Phase Distribution and Partition Efficiency in Coaxial CoilsSeparation Science and Technology, 1987
- Cross-Axis Synchronous Flow-Through Coil Planet Centrifuge Free of Rotary Seals for Preparative Countercurrent Chromatography. Part I. Apparatus and Analysis of AccelerationSeparation Science and Technology, 1987