Calibration of rotation axes for multi-axis goniometers in macromolecular crystallography
Open Access
- 13 September 2018
- journal article
- research article
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 51 (5) , 1421-1427
Abstract
The installation of multi-axis goniometers such as the ESRF/EMBL miniKappa goniometer system has allowed the increased use of sample reorientation in macromolecular crystallography. Old and newly appearing data collection methods require precision and accuracy in crystal reorientation. The proper use of such multi-axis systems has necessitated the development of rapid and easy to perform methods for establishing and evaluating device calibration. A new diffraction-based method meeting these criteria has been developed for the calibration of the motors responsible for rotational motion. This method takes advantage of crystal symmetry by comparing the orientations of a sample rotated about a given axis and checking that the magnitude of the real rotation fits the calculated angle between these two orientations. Hence, the accuracy and precision of rotational motion can be assessed. This rotation calibration procedure has been performed on several beamlines at the ESRF and other synchrotrons. Some resulting data are presented here for reference.Keywords
This publication has 34 references indexed in Scilit:
- The use of a mini-κ goniometer head in macromolecular crystallography diffraction experimentsActa Crystallographica Section D Structural Biology, 2013
- The use of workflows in the design and implementation of complex experiments in macromolecular crystallographyActa Crystallographica Section D Structural Biology, 2012
- Translation calibration of inverse-kappa goniometers in macromolecular crystallographyActa Crystallographica Section A Foundations of Crystallography, 2011
- X-ray absorption, refraction and resonant scattering tensors in selenated protein crystals: implications for data collection strategies in macromolecular crystallographyJournal of Applied Crystallography, 2005
- New Method for Extracting the Quaternion from a Rotation MatrixJournal of Guidance, Control, and Dynamics, 2000
- Data-collection strategiesActa Crystallographica Section D Structural Biology, 1999
- [21] Data collection strategy1997
- A procedure for determining rigid body transformation parametersJournal of Biomechanics, 1995
- On choosing off-line automatic X-ray diffractometersJournal of Applied Crystallography, 1968
- Angle calculations for 3- and 4-circle X-ray and neutron diffractometersActa Crystallographica, 1967