Aim : Although distal embolization during percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI) deteriorates cardiac function, whether distal protection (DP) can improve prognosis is still controversial. We investigated whether a filter-type DP device, Filtrap®, could improve long-term outcomes after PCI for AMI. Method : We studied 164 patients (130 men, mean age: 65.7 years) who underwent PCI. Patients were divided into two groups based on the use of Filtrap®. The occurrence of congestive heart failure (CHF) and major adverse cardiac events (MACE) defined as cardiac death, recurrent AMI, and target vessel revascularization were compared. Result : Between DP (n=53, 41 men, mean age: 65.5 years) and non-DP (n=111, 89 men, mean age: 65.8 years) groups, although there was significantly greater plaque area in the DP group than in the non-DP group, there were no significant differences in coronary reperfusion flow after PCI. Interestingly, patients with CHF in the non-DP group exhibited a higher CK level than those in the DP group. During a 2-year follow-up period, cumulative CHF was significantly lower in the DP group than in the non-DP group (log-rank p=0.018), and there was no significant difference in the MACE rate (log-rank p=0.238). The use of DP device could not predict MACE, but could predict CHF by multivariate analysis (odds ratio=0.099, 95% CI: 0.02–0.42, p=0.005). Conclusion : These results demonstrate that favorable clinical outcomes could be achieved by the filter-type DP device in AMI, particularly in patients with CHF.Keywords
This publication has 35 references indexed in Scilit:
- Randomized Comparison of Distal Protection Versus Conventional Treatment in Primary Percutaneous Coronary InterventionJACC, 2008
- Comparison of myocardial perfusion by distal protection before and after primary stenting for acute myocardial infarction: Angiographic and clinical results of a randomized controlled trialCatheterization and Cardiovascular Interventions, 2007
- Adjunctive mechanical devices to prevent distal embolization in patients undergoing mechanical revascularization for acute myocardial infarction: A meta-analysis of randomized trialsAmerican Heart Journal, 2007
- Relation of Atherothrombosis Burden and Volume Detected by Intravascular Ultrasound to Angiographic No-Reflow Phenomenon During Stent Implantation in Patients With Acute Myocardial InfarctionThe American Journal of Cardiology, 2006
- Comparison of Coronary Arterial Finding by Intravascular Ultrasound in Patients With “Transient No-Reflow” Versus “Reflow” During Percutaneous Coronary Intervention in Acute Coronary SyndromeThe American Journal of Cardiology, 2006
- Randomized Evaluation of the Effects of Filter-Based Distal Protection on Myocardial Perfusion and Infarct Size After Primary Percutaneous Catheter Intervention in Myocardial Infarction With and Without ST-Segment ElevationCirculation, 2005
- Distal protection in native coronary arteries during primary angioplasty in acute myocardial infarction: Single‐center experienceCatheterization and Cardiovascular Interventions, 2003
- Mechanical Prevention of Distal Embolization During Primary AngioplastyCirculation, 2003
- The Thrombolysis in Myocardial Infarction (TIMI) TrialNew England Journal of Medicine, 1985
- Changes in collateral channel filling immediately after controlled coronary artery occlusion by an angioplasty balloon in human subjectsJACC, 1985