Abstract
Background Endotracheal tube (ETT) tip position is determined on chest X-ray (CXR) and should lie between the upper border of the first thoracic vertebra (T1) and the lower border of second thoracic vertebra (T2). Infant weight is commonly used to estimate how far the ETT should be inserted but frequently results in malpositioned ETT tips. Palpation of the ETT tip at the suprasternal notch has been recommended as an alternative. Objective To determine whether estimating ETT insertion depth using suprasternal palpation of the ETT tip rather than weight results in more correctly positioned ETT tips. Design Single-centre randomised controlled trial. Setting Level III neonatal intensive care unit (NICU) at a university maternity hospital. Patients Newborn infants without congenital anomalies intubated in the NICU. Interventions Participants were randomised to have ETT insertion depth estimated using palpation of the ETT tip at the suprasternal notch or weight [insertion depth (cm)=6 + wt (kg)]. Main outcome measure Correct ETT position, that is, between the upper border of T1 and lower border of T2 on CXR, determined by one consultant paediatric radiologist masked to group assignment. Results There was no difference in the proportion of correctly placed ETT tips between the groups (suprasternal palpation 27/58 (47%) vs weight 23/60 (38%), p=0.456). Most incorrectly positioned ETTs were too low (56/68 (82%)). Conclusion Estimating ETT insertion depth using suprasternal palpation did not result in more correctly positioned ETTs. Trial registration number ISRCTN13570106.Keywords
Funding Information
- National Children’s Research Centre, Dublin, Ireland
This publication has 34 references indexed in Scilit:
- Digital palpation of endotracheal tube tip as a method of confirming endotracheal tube position in neonates: an open‐label, three‐armed randomized controlled trialPediatric Anesthesia, 2013
- Ultrasound Confirmation of Endotracheal Tube Position in NeonatesNeonatology, 2012
- Endotracheal tube length for neonatal intubationResuscitation, 2008
- Optimal Endotracheal Tube Tip Position in Extremely Premature InfantsAmerican Journal of Perinatology, 2007
- Endotracheal Tube Position in Neonates Requiring Emergency Interhospital TransferAmerican Journal of Perinatology, 2006
- A randomized trial of suprasternal palpation to determine endotracheal tube position in neonatesResuscitation, 2004
- Foot length, an accurate predictor of nasotracheal tube length in neonatesArchives of Disease in Childhood - Fetal and Neonatal Edition, 2001
- Presumed consent in emergency neonatal researchJournal of Medical Ethics, 2000
- First thoracic vertebral body as reference for endotracheal tube placement.Archives of Disease in Childhood - Fetal and Neonatal Edition, 1994
- Orotracheal intubation in the newborn infant: A method for determining depth of tube insertionThe Journal of Pediatrics, 1979