Development and experimental evaluation of an IoT-based closed-loop system for PM2.5 monitoring and automated electrical ionization actuation
Open Access
- 8 October 2026
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Sustainability
- Vol. 7, 1939212
Abstract
Fine particulate matter (PM2.5) remains a major environmental health concern in Thailand and motivates the development of monitoring systems that can support localized, automated responses. This research presents and experimentally evaluates Cleara-Air , an integrated Internet of Things (IoT) and Web-GIS closed-loop system for real-time particulate-matter monitoring and threshold-based electrical ionization actuation. The system integrates an ESP32 microcontroller, a Sensirion SPS30 particulate sensor, a 4-channel 5V relay, a 220V AC ventilation fan, and a carbon-brush negative-anion generator, with PostgreSQL-based data storage and a responsive Web Map Application. The controller continuously acquires particulate measurements and uses 37.5 μg/m 3 as an operational PM2.5 set-point when the measured concentration exceeds this value, the relay activates the fan and ionization module, and the actuators are deactivated when the concentration subsequently falls below the set-point. The integrated workflow was evaluated through 15 repeated closed-room functional trials in which particulate concentrations were intentionally elevated near the SPS30 sensor. The evaluation examined threshold detection, actuator activation and deactivation, 15-s data transmission, database logging, and Web-GIS status visualization. The repeated tests demonstrated that the programmed sensing-processing-communication-actuation sequence operated as intended under the tested conditions, providing original experimental evidence of the functional performance of the integrated closed-loop architecture. The study evaluates system functionality rather than PM2.5 removal efficacy quantitative treatment-vs.-control experiments, reference-grade sensor calibration, and direct ozone measurements remain necessary before claims regarding mitigation effectiveness or operational safety can be made. The results establish Cleara-Air as an experimentally evaluated prototype framework for integrating real-time environmental sensing, automated control, and geospatial information delivery.Keywords
This publication has 32 references indexed in Scilit:
- Internet of things for monitoring air pollution PM 2.5: A bibliometric analysisAIP Conference Proceedings, 2026
- Sensor-based Approaches for Indoor Air Quality Monitoring and Control: PM2.5 and PM102025
- Strategy for coordinating near-term PM 2.5 , ozone, and CO 2 mitigation in ChinaProceedings of the National Academy of Sciences, 2025
- Development of a federated learning-enabled IoT framework for indoor air quality and HVAC optimization in healthcare buildingsJournal of Building Engineering, 2025
- Geo-spatial distribution of air pollutants in urban area and its potential health risk analysis solutionsUrban Climate, 2025
- A systematic review with a Burden of Proof meta-analysis of health effects of long-term ambient fine particulate matter (PM2.5) exposure on dementiaNature Aging, 2025
- Analysis of China's PM2.5 and ozone coordinated control strategy based on the observation data from 2015 to 2020Journal of Environmental Sciences, 2023
- Development of IoT based smart monitor and control system using MQTT protocol and Node-RED for parabolic greenhouse solar dryingInternational Journal of Information Technology, 2023
- The health effects of ambient PM2.5 and potential mechanismsEcotoxicology and Environmental Safety, 2016
- Characterization of PM2.5, PM2.5–10 and PM>10 in ambient air, Yokohama, JapanAtmospheric Research, 2010