Ten water-soluble ions (F−, Cl−, NO2 −, NO3 −, SO4 2−, K+, Na+, NH4 +, Ca2+, and Mg2+) in PM2.5 samples were determined by capillary electrophoresis (CE) with a resonant capacitively coupled contactless conductive detector (RC4D). The main component of the background electrolyte (BGE) solution was 20 mM 2-morpholinoethanesulfonic acid (MES)/L-histidine (His) (pH = 6.1). The modifiers of 1.5 mM 18-crown-6 and 20 μM CTAB were added to the BGE for the separation of cations and anions, respectively. The limit of detection for the ten ions is in the range of 3–20 μg L−1. In the combination of dual-opposite end injection and end-to-end differential detection, simultaneous determination of the ten ions was performed in a BGE of 20 mM MES/His + 1.5 mM 18-crown-6 + 20 μM CTAB. A flow injection interface was employed for delay of sample injection without interrupting the electrophoresis. The negative peaks appeared in the early and later stages of electrophoresis increase the possibility of peak superposition in electropherograms. With two independent separation capillaries employed in end-to-end differential detection, simultaneous determination of anions and cations was performed with optimized BGE and better peak separation.Keywords
This publication has 53 references indexed in Scilit:
- Recent developments in electromembrane extractionAnalytical Methods, 2013
- Portable Capillary Electrophoresis Instrument with Automated Injector and Contactless Conductivity DetectionAnalytical Chemistry, 2013
- Spatial and seasonal variability of water-soluble ions in PM2.5 aerosols in 14 major cities in ChinaAtmospheric Environment, 2012
- Capacitively coupled contactless conductivity detection on microfluidic systems—ten years of developmentAnalytical Methods, 2011
- Capillary electrophoresis procedure for the simultaneous analysis and stoichiometry determination of a drug and its counter-ion by using dual-opposite end injection and contactless conductivity detection: Application to labetalol hydrochlorideAnalytica Chimica Acta, 2010
- Zwitterionic ion-exchangers in ion chromatography: A review of recent developmentsAnalytica Chimica Acta, 2009
- Modeling Pareto efficient PM10 control policies in Northern Italy to reduce health effectsAtmospheric Environment, 2009
- Long-term visibility trends in one highly urbanized, one highly industrialized, and two Rural areas of TaiwanScience of The Total Environment, 2007
- Electrophoretic microchip with dual‐opposite injection for simultaneous measurements of anions and cationsElectrophoresis, 2003
- Frequency Distributions of PM10 Chemical Components and Their SourcesEnvironmental Science & Technology, 1995