Measuring tidal breathing parameters using a volumetric vest in neonates with and without lung disease
Authors:
Open Access
- 24 September 2010
- journal article
- research article
- Published by Wiley in Pediatric Pulmonology
- Vol. 45 (11) , 1070-1075
Abstract
Lung function measurement is difficult in unsedated infants; tidal breathing parameters are a useful non‐invasive surrogate, but even these measurements cause disturbance from applying a facemask. We investigated a novel volumetric vest system (FloRight), which measures volume changes of the respiratory system from changes in the magnetic fields induced by current‐carrying coils around the entire chest and abdomen. Using a facemask and ultrasonic flowmeter as comparator, we assessed the validity and repeatability of tidal breathing parameters measured by FloRight in 10 healthy newborn infants during natural sleep. We also assessed the effect of a facemask on tidal volume and tidal expiratory flow parameters. To assess the ability of the FloRight system to detect disease, we compared the healthy infants with 11 infants suffering from bronchopulmonary dysplasia. Tidal parameters with the FloRight vest corresponded closely with facemask measurements. Mean difference, mask minus vest, for tidal volume was 0.096 ml (P < 0.05), with limits of agreement +4.5 to −4.3 ml. Coefficient of repeatability was similar for mask and vest measurements. Tidal volume measured by FloRight with mask in place (20.6 ml) was significantly higher than without mask (16.1 ml), but tidal expiratory flow parameters were not altered. FloRight measurements of tidal parameters were markedly different between the two groups of infants, with tidal volume per Kg significantly higher and tidal expiratory flow parameters significantly lower. Our findings suggest that the FloRight system is able to measure tidal breathing parameters accurately, in healthy newborn infants, without prior calibration on the infant. It appears to have at least sufficient sensitivity to detect severe respiratory disease. Pediatr Pulmonol. 2010;45:1070–1075.Keywords
This publication has 13 references indexed in Scilit:
- Lung function testing in infants with cystic fibrosis: Lessons from the past and future directionsPediatric Pulmonology, 2001
- Tidal breath analysis for infant pulmonary function testingEuropean Respiratory Journal, 2000
- Do Tidal Expiratory Flow Patterns Reflect Lung Mechanics in Infants?American Journal of Respiratory and Critical Care Medicine, 1996
- A critical assessment of uncalibrated respiratory inductance plethysmography (Respitrace®) for the measurement of tidal breathing parameters in newborns and infantsPediatric Pulmonology, 1995
- Analysis of Tidal Breathing Parameters in Infancy: How Variable Is TPTEF:TE?American Journal of Respiratory and Critical Care Medicine, 1994
- Lung function by tidal breathing in awake healthy newborn infantsEuropean Respiratory Journal, 1994
- Validation of respiratory inductance plethysmography (“Respitrace”®) for the measurement of tidal breathing parameters in newbornsPediatric Pulmonology, 1992
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Changes in Respiratory Pattern Resulting from the Use of a Facemask to Record Respiration in Newborn InfantsPediatric Research, 1982
- Tidal expiratory flow patterns in airflow obstruction.Thorax, 1981