Abstract
The effect of the quality of the bone and of the cement pressurization magnitude and duration on the fixation achieved with polymethylmethacrylate (PMMA) bone cement is studied in vitro. Seventy‐one cementbone interface specimens, prepared under various conditions of pressurization of low‐viscosity bone cement, are tested in tension. The load at failure and the maximum cement penetration are measured to assess the fixation achieved, and the quality of the bone is assessed by determining the compressive strength of each of the bone specimens. Statistical analysis of the data indicates that the pressure magnitude is the most influential of the factors considered in the cement penetration behavior and in the development of failure load capacity. The duration of the pressure does not appear to be a significant factor. The cement penetration is a decreasing function of the bone strength, reflecting a decrease in the porosity and an increase in the area fraction. Although not directly measured in these tests, these latter bone properties are indirectly measured by the bone compressive strength. The effect of increasing bone strength on the failure load is nonlinear. The development of adequate failure load capacity is the result of a balance between the cement penetration allowed by the porosity of the bone and the inherent strength of the cancellous bone itself. Weak bone, although adequately penetrated by cement, cannot provide strong fixation. Stronger, denser bone limits cement penetration, but pressurization enhances development of failure load capacity through more complete infusion and interlocking of the cement in the available pore space. The strength of the fixation achievable for any bone is limited by the intrinsic strength of the bone. An optimal depth of cement penetration of 4 mm and an optimal bone area fraction of 0.20 are suggested for the most effective fixation.Keywords
This publication has 8 references indexed in Scilit:
- Mechanical strength of poly(methyl methacrylate) cement‐human bone interfacesJournal of Biomedical Materials Research, 1983
- Penetration of Acrylic Bone Cements into Cancellous BoneActa Orthopaedica, 1983
- Strength of the Cement-Bone InterfaceClinical Orthopaedics and Related Research, 1982
- Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial EpiphysisJournal of Biomechanical Engineering, 1982
- The shear strength of trabecular bone from the femur, and some factors affecting the shear strength of the cement-bone interfaceArchives of orthopaedic and trauma surgery, 1978
- The compressive behavior of bone as a two-phase porous structureJournal of Bone and Joint Surgery, 1977
- Penetration and Flow of Acrylic Bone CementClinical Orthopaedics and Related Research, 1976
- Mechanical strength of acrylic bone cements impregnated with antibioticsJournal of Biomedical Materials Research, 1976