Direct-drive induction motors: using an induction motor as an alternative to a motor with reducer
Authors:
- 27 June 2005
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Industry Applications Magazine
- Vol. 11 (4) , 45-51
Abstract
This article presents the performance and size comparisons of direct-drive induction motors with gearbox-driven systems. Three different low-speed applications with output speeds to the driven equipment ranging from 300-600 r/min is reviewed. In addition, permanent-magnet (PM) motor advantages and disadvantages are also discussed.Keywords
This publication has 6 references indexed in Scilit:
- A Motor Primer - Part 62007
- Direct drive-opening a new era in many applications2003
- A motor primer. I2003
- Variable frequency drive principles and practices (above NEMA) AC motors for variable frequency application2003
- Optimum pole configuration of AC induction motors used on adjustable frequency power supplies2002