Joint gap produced by manual stress is dependent on the surgeon’s experience and is smaller in flexion in robotic‐assisted total knee arthroplasty
Authors:
- 15 August 2022
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 31 (3) , 963-968
Abstract
Purpose: This study aimed to retrospectively investigate (1) the reproducibility of gap measurements by manual stress using the Z‐shaped retractor depending on the surgeon’s experience with this maneuver and (2) the consistency of the gap distraction force produced by manual stress throughout the range of motion (ROM) in the robotic‐assisted total knee arthroplasty (TKA). It was hypothesized that the joint gap produced by manual stress is not reproducible depending on the surgeon’s experience, and the distraction force applied by manual stress throughout the ROM is not constant.Methods: Medial and lateral joint gaps were obtained throughout the ROM by manual stress or a tensioner by two surgeons with different levels of experience in robotic‐assisted TKA. The association between the differences in gap measurement by the two surgeons and the preoperative radiographic parameters, including the hip‐knee‐ankle (HKA) angle and absolute and relative varus/valgus laxities were analyzed.Results: The experienced surgeon produced significantly greater gaps than the inexperienced surgeon from 0° to 100° flexion, with a mean difference of 0.35 ± 0.12 mm in the medial gap (p < 0.0001), and from 10° to 120° flexion with a mean difference of 0.57 ± 0.13 mm in the lateral gap (p < 0.0001). The tensioner produced a significantly greater medial gap from 70° to 110° flexion with a mean difference of 0.32 ± 0.01 mm in the medial gap (p < 0.0001) and from 0° to 110° flexion with a mean difference of 1.12 ± 0.26 mm in the lateral gap (p < 0.0001). The differences in gap distance by manual stress between experienced and inexperienced surgeons were moderately correlated with the HKA angle in the lateral gap (r = 0.40, p = 0.01). The gap differences due to manual stress and a tensioner showed moderate negative correlation with the HKA angle in the medial gap (r = − 0.50, p = 0.001) and weak negative correlation with the absolute valgus laxity in the lateral gap (r = − 0.35, p = 0.03).Conclusions: The joint distraction force by manual stress may differ depending on the surgeon’s experience and tended to be smaller in deep flexion; therefore, the flexion gap may be underestimated. Surgeons should determine implant positioning considering gap balance by manual stress, taking into account these characteristics of the manual stress maneuver.Level of evidence: Level III, retrospective cohort study.Keywords
This publication has 22 references indexed in Scilit:
- Preoperative varus laxity correlates with overcorrection in medial opening wedge high tibial osteotomyArchives of orthopaedic and trauma surgery, 2016
- Are ligament-tensioning devices interchangeable? A study of femoral rotationOrthopaedics & Traumatology: Surgery & Research, 2016
- Patient-related factors influence stiffness of the soft tissue complex during intraoperative gap balancing in cruciate-retaining total knee arthroplastyKnee Surgery, Sports Traumatology, Arthroscopy, 2015
- Robotic-assisted TKA Reduces Postoperative Alignment Outliers and Improves Gap Balance Compared to Conventional TKAClinical Orthopaedics and Related Research, 2013
- Lateral Soft Tissue Laxity Increases but Medial Laxity Does Not Contract With Varus Deformity in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2012
- Development of a Pneumatic Tensioning Device for Gap Measurement during Total Knee ArthroplastyClinics in Orthopedic Surgery, 2012
- The Influence of Preoperative Deformity on Intraoperative Soft Tissue Balance in Posterior-Stabilized Total Knee ArthroplastyThe Journal of Arthroplasty, 2011
- Bone Landmarks Are More Reliable Than Tensioned Gaps in TKA Component AlignmentClinical Orthopaedics and Related Research, 2007
- Automated hydraulic tensor for Total Knee ArthroplastyThe International Journal of Medical Robotics and Computer Assisted Surgery, 2005
- Posterior-stabilized versus cruciate-retaining total knee arthroplastyThe Journal of Arthroplasty, 2002