Detection of intravenous infiltration using impedance parameters in patients in a long-term care hospital
Authors:
Open Access
- 21 March 2019
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (3) , e0213585
Abstract
This study was aimed to evaluate the changes of impedance parameters of patients who were admitted to a long-term care hospital by measuring bioelectrical impedance. The subjects were 18 patients who had infusion therapy through peripheral intravenous (IV) catheters and had at least an infiltration. The impedance parameters were measured with a multi-channel impedance measuring instrument (Vector Impedance Meter) twice; at starting IV infusion after catheter insertion and infiltration detected. As results, the resistance (R) after infiltration significantly decreased compared to the initial resistance. At 50 kHz, the resistances were 498.2±79.3 [Ω] before infiltration and 369.4±85.6 [Ω] after infiltration. The magnitude of the reactance (XC) decreased after infiltration. At 50 kHz, the measured reactance was -31.1±8.3 [Ω] before infiltration and -24.5±5.9 [Ω] after infiltration. The data points plotted in the R-XC graph shifted from the first quadrant before infiltration to third quadrant after infiltration. Our findings suggest that bioelectrical impedance is an effective method for detection of infiltration in a noninvasive and quantitative manner.Keywords
Funding Information
- the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and Future Planning (2015R1A2A2A04003415)
This publication has 15 references indexed in Scilit:
- Obtaining electrical equivalent circuits of biological tissues using the current interruption method, circuit theory and fractional calculusRSC Advances, 2016
- Bioelectrical Impedance Analysis at Popliteal Regions of Human Body using BIMSJournal of Sensor Science and Technology, 2016
- Effects of muscle injury severity on localized bioimpedance measurementsPhysiological Measurement, 2014
- Bioelectrical impedance vector analysis (BIVA) for the assessment of two-compartment body compositionEuropean Journal of Clinical Nutrition, 2014
- The Theory and Fundamentals of Bioimpedance Analysis in Clinical Status Monitoring and Diagnosis of DiseasesSensors, 2014
- High-resolution ultrasound imaging of cutaneous lesionsIndian Journal of Radiology and Imaging, 2013
- Localized bioimpedance to assess muscle injuryPhysiological Measurement, 2013
- Routine versus clinically indicated replacement of peripheral intravenous catheters: a randomised controlled equivalence trialThe Lancet, 2012
- European Oncology Nursing Society extravasation guidelinesEuropean Journal of Oncology Nursing, 2008
- Infiltration and ExtravasationAJN, American Journal of Nursing, 2007