EEG artifact removal—state-of-the-art and guidelines
Top Cited Papers
- 2 April 2015
- journal article
- review article
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 12 (3) , 031001
Abstract
This paper presents an extensive review on the artifact removal algorithms used to remove the main sources of interference encountered in the electroencephalogram (EEG), specifically ocular, muscular and cardiac artifacts. We first introduce background knowledge on the characteristics of EEG activity, of the artifacts and of the EEG measurement model. Then, we present algorithms commonly employed in the literature and describe their key features. Lastly, principally on the basis of the results provided by various researchers, but also supported by our own experience, we compare the state-of-the-art methods in terms of reported performance, and provide guidelines on how to choose a suitable artifact removal algorithm for a given scenario. With this review we have concluded that, without prior knowledge of the recorded EEG signal or the contaminants, the safest approach is to correct the measured EEG using independent component analysis—to be precise, an algorithm based on second-order statistics such as second-order blind identification (SOBI). Other effective alternatives include extended information maximization (InfoMax) and an adaptive mixture of independent component analyzers (AMICA), based on higher order statistics. All of these algorithms have proved particularly effective with simulations and, more importantly, with data collected in controlled recording conditions. Moreover, whenever prior knowledge is available, then a constrained form of the chosen method should be used in order to incorporate such additional information. Finally, since which algorithm is the best performing is highly dependent on the type of the EEG signal, the artifacts and the signal to contaminant ratio, we believe that the optimal method for removing artifacts from the EEG consists in combining more than one algorithm to correct the signal using multiple processing stages, even though this is an option largely unexplored by researchers in the area.Keywords
Funding Information
- Bizkaia Talent (267230)
This publication has 128 references indexed in Scilit:
- High-frequency brain activity and muscle artifacts in MEG/EEG: a review and recommendationsFrontiers in Human Neuroscience, 2013
- Independent EEG Sources Are DipolarPLOS ONE, 2012
- Electromyogenic artifacts and electroencephalographic inferences revisitedNeuroImage, 2011
- Validation of ICA-based myogenic artifact correction for scalp and source-localized EEGNeuroImage, 2010
- Validation of regression‐based myogenic correction techniques for scalp and source‐localized EEGPsychophysiology, 2009
- Electromyogenic Artifacts and Electroencephalographic InferencesBrain Topography, 2009
- Review on solving the inverse problem in EEG source analysisJournal of NeuroEngineering and Rehabilitation, 2008
- The Correction of Eye Blink Artefacts in the EEG: A Comparison of Two Prominent MethodsPLOS ONE, 2008
- Enhanced detection of artifacts in EEG data using higher-order statistics and independent component analysisNeuroImage, 2007
- Fast and robust fixed-point algorithms for independent component analysisIEEE Transactions on Neural Networks, 1999