A biomimetic tumor tissue phantom for validating diffusion‐weighted MRI measurements
Open Access
- 20 November 2017
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 80 (1) , 147-158
Abstract
Purpose: To develop a biomimetic tumor tissue phantom which more closely reflects water diffusion in biological tissue than previously used phantoms, and to evaluate the stability of the phantom and its potential as a tool for validating diffusion‐weighted (DW) MRI measurements.Methods: Coaxial‐electrospraying was used to generate micron‐sized hollow polymer spheres, which mimic cells. The bulk structure was immersed in water, providing a DW‐MRI phantom whose apparent diffusion coefficient (ADC) and microstructural properties were evaluated over a period of 10 months. Independent characterization of the phantom's microstructure was performed using scanning electron microscopy (SEM). The repeatability of the construction process was investigated by generating a second phantom, which underwent high resolution synchrotron‐CT as well as SEM and MR scans.Results: ADC values were stable (coefficients of variation (CoVs) < 5%), and varied with diffusion time, with average values of 1.44 ± 0.03 µm2/ms (Δ = 12 ms) and 1.20 ± 0.05 µm2/ms (Δ = 45 ms). Microstructural parameters showed greater variability (CoVs up to 13%), with evidence of bias in sphere size estimates. Similar trends were observed in the second phantom.Conclusion: A novel biomimetic phantom has been developed and shown to be stable over 10 months. It is envisaged that such phantoms will be used for further investigation of microstructural models relevant to characterizing tumor tissue, and may also find application in evaluating acquisition protocols and comparing DW‐MRI‐derived biomarkers obtained from different scanners at different sites. Magn Reson Med 80:147–158, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.Keywords
Funding Information
- BBSRC (BB/F011350/1)
- Engineering and Physical Sciences Research Council (EP/M023877/1)
This publication has 66 references indexed in Scilit:
- The role of tissue microstructure and water exchange in biophysical modelling of diffusion in white matterMagnetic Resonance Materials in Physics, Biology and Medicine, 2013
- Diffusion coefficient measurement using a temperature‐controlled fluid for quality control in multicenter studiesJournal of Magnetic Resonance Imaging, 2011
- Electrospray deposition and direct patterning of polylactic acid nanofibrous microcapsules for tissue engineeringBiomedical Microdevices, 2011
- Poly Lactic-co-Glycolic Acid (PLGA) as Biodegradable Controlled Drug Delivery CarrierPolymers, 2011
- Dependence of temporal diffusion spectra on microstructural properties of biological tissuesMagnetic Resonance Imaging, 2011
- Effective medium theory of a diffusion‐weighted signalNMR in Biomedicine, 2010
- Characterization of tissue structure at varying length scales using temporal diffusion spectroscopyNMR in Biomedicine, 2010
- Assessment of the effects of cellular tissue properties on ADC measurements by numerical simulation of water diffusionMagnetic Resonance in Medicine, 2009
- Integration of quantitative DCE-MRI and ADC mapping to monitor treatment response in human breast cancer: initial resultsMagnetic Resonance Imaging, 2007
- Differentiation of clinically benign and malignant breast lesions using diffusion‐weighted imagingJournal of Magnetic Resonance Imaging, 2002