A Large-Scale Evaluation into the Accuracy of Bioelectrical Impedance Devices for Assessing Body Composition: A 10-Year Analysis in Canadian University Students
- 7 November 2025
- journal article
- Published by Index Copernicus in Journal of Kinesiology and Exercise Sciences
Abstract
Background: The assessment of body composition can be conducted using a variety of devices, each providing practitioners unique advantages such as cost effectiveness, efficiency, accessibility, and accuracy. The purpose of this study was to evaluate the precision of three bioelectrical impedance analysis (BIA) devices when compared to air displacement plethysmography (BOD POD). Methods: A large-scale study involving 617 undergraduate kinesiology students (♀ = 342 | ♂ = 275) participated in this study. Participants had a mean ( SD) age of 21.2 2.0 y, a height of 171.9 9.9 cm, and a weight of 71.6 15.2 kg. Each participant completed a body composition assessment using the following BIA equipment: Tanita BC-568, Tanita BF-683W, and InBody 230 to estimate body fat (%). Air plethysmography (BOD POD) was used as the criterion method for deriving body composition. Order of assessments were randomized and were performed 1hr apart on the same day. Results: All data sets were positively skewed and determined to be non-normally distributed after conducting a Shapiro-wilk assessment (p < 0.05). Statistically significant differences in the mean absolute error between the criterion and each BIA device were observed: Tanita-568 (MAE = 4.8, p < 0.0001), Tanita-683 (MAE = 5.8, p < 0.0001) and InBody 230 (MAE = 4.6, p = 0.046). The calculated effect size between each BIA device and the criterion revealed trivial differences (ES 0.16). Conclusion: Overall, the InBody 230 BIA device displayed the strongest agreement with the BOD POD.Keywords
This publication has 35 references indexed in Scilit:
- Reference data on anthropometrics, aerobic fitness and muscle strength in young Norwegian men and womenEuropean Journal of Applied Physiology, 2021
- Comparison of Body Composition Assessment Using Air-Displacement Plethysmography and A-Mode Ultrasound before and after a 12-Week Exercise Intervention in Normal Weight Adult MalesMeasurement in Physical Education and Exercise Science, 2020
- Knowledge of physical activity and nutrition recommendations in college studentsJournal of American College Health, 2020
- Current technologies in body composition assessment: advantages and disadvantagesNutrition, 2019
- Body composition: Why, when and for who?Clinical Nutrition, 2012
- Reliability and Intermethod Agreement for Body Fat Assessment Among Two Field and Two Laboratory Methods in AdolescentsObesity, 2012
- Interdevice variability in percent fat estimates using the BOD PODEuropean Journal of Clinical Nutrition, 2005
- Assessing Body Composition among 3‐ to 8‐Year‐Old Children: Anthropometry, BIA, and DXAObesity Research, 2004
- Techniques of Body Composition Assessment: A Review of Laboratory and Field MethodsResearch Quarterly for Exercise and Sport, 1999
- Why bioelectrical impedance analysis should be used for estimating adiposityThe American Journal of Clinical Nutrition, 1996