Meta-analytic estimation of measurement variability and assessment of its impact on decision-making: the case of perioperative haemoglobin concentration monitoring
Open Access
- 19 January 2016
- journal article
- research article
- Published by Springer Nature in BMC Medical Research Methodology
- Vol. 16 (1) , 7
Abstract
Background As a part of a larger Health Technology Assessment (HTA), the measurement error of a device used to monitor the hemoglobin concentration of a patient undergoing surgery, as well as its decision consequences, were to be estimated from published data. Methods A Bayesian hierarchical model of measurement error, allowing the meta-analytic estimation of both central and dispersion parameters (under the assumption of normality of measurement errors) is proposed and applied to published data; the resulting potential decision errors are deduced from this estimation. The same method is used to assess the impact of an initial calibration. Results The posterior distributions are summarized as mean ± sd (credible interval). The fitted model exhibits a modest mean expected error (0.24 ± 0.73 (−1.23 1.59) g/dL) and a large variability (mean absolute expected error 1.18 ± 0.92 (0.05 3.36) g/dL). The initial calibration modifies the bias (−0.20 ± 0.87 (−1.99 1.49) g/dL), but the variability remains almost as large (mean absolute expected error 1.05 ± 0.87 (0.04 3.21) g/dL). This entails a potential decision error (“false positive” or “false negative”) for about one patient out of seven. Conclusions The proposed hierarchical model allows the estimation of the variability from published aggregates, and allows the modeling of the consequences of this variability in terms of decision errors. For the device under assessment, these potential decision errors are clinically problematic.Keywords
This publication has 31 references indexed in Scilit:
- Transfusion thresholds and other strategies for guiding allogeneic red blood cell transfusion2012
- Evaluation of Pulse Cooximetry in Patients Undergoing Abdominal or Pelvic SurgeryAnesthesiology, 2012
- Continuous Noninvasive Hemoglobin Monitoring During Complex Spine SurgeryAnesthesia & Analgesia, 2011
- Comparison of the Accuracy of Noninvasive Hemoglobin Monitoring by Spectrophotometry (SpHb) and HemoCue® with Automated Laboratory Hemoglobin MeasurementAnesthesiology, 2011
- Validation of noninvasive hemoglobin measurements using the Masimo Radical-7 SpHb StationThe American Journal of Surgery, 2011
- A Comparison of Three Methods of Hemoglobin Monitoring in Patients Undergoing Spine SurgeryAnesthesia & Analgesia, 2011
- Prior distributions for variance parameters in hierarchical models (comment on article by Browne and Draper)Bayesian Analysis, 2006
- Meta‐analysis of method comparison studiesStatistics in Medicine, 2002
- Examining Correlates of DiversityJournal of Educational Statistics, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986