Generalized separable parameter space techniques for fitting 1K‐5K serial compartment models
Authors:
Open Access
- 24 June 2013
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 40 (7) , 072502
Abstract
Purpose:: Kinetic modeling is widely used to analyze dynamic imaging data, estimating kinetic parameters that quantify functional or physiologic processesin vivo. Typical kinetic models give rise to nonlinear solution equations in multiple dimensions, presenting a complex fitting environment. This work generalizes previously described separable nonlinear least‐squares techniques for fitting serial compartment models with up to three tissue compartments and five rate parameters.Methods:: The approach maximally separates the linear and nonlinear aspects of the modeling equations, using a formulation modified from previous basis function methods to avoid a potential mathematical degeneracy. A fast and robust algorithm for solving the linear subproblem with full user‐defined constraints is also presented. The generalized separable parameter space technique effectively reduces the dimensionality of the nonlinear fitting problem to one dimension for 2K‐3K compartment models, and to two dimensions for 4K‐5K models.Results:: Exhaustive search fits, which guarantee identification of the true global minimum fit, required approximately 10 ms for 2K‐3K and 1.1 s for 4K‐5K models, respectively. The technique is also amenable to fast gradient‐descent iterative fitting algorithms, where the reduced dimensionality offers improved convergence properties. The objective function for the separable parameter space nonlinear subproblem was characterized and found to be generally well‐behaved with a well‐defined global minimum. Separable parameter space fits with the Levenberg‐Marquardt algorithm required fewer iterations than comparable fits for conventional model formulations, averaging 1 and 7 ms for 2K‐3K and 4K‐5K models, respectively. Sensitivity to initial conditions was likewise reduced.Conclusions:: The separable parameter space techniques described herein generalize previously described techniques to encompass 1K‐5K compartment models, enable robust solution of the linear subproblem with full user‐defined constraints, and are amenable to rapid and robust fitting using iterative gradient‐descent type algorithms.Keywords
Funding Information
- National Cancer Institute (R01CA135556)
- National Cancer Institute (R01CA135556)
This publication has 31 references indexed in Scilit:
- Parametric Mapping of [18F]Fluoromisonidazole Positron Emission Tomography using Basis FunctionsJournal of Cerebral Blood Flow & Metabolism, 2010
- Voxel-Based Estimation of Kinetic Model Parameters of the l-[1-11C]Leucine PET Method for Determination of Regional Rates of Cerebral Protein Synthesis: Validation and Comparison with Region-of-Interest-Based MethodsJournal of Cerebral Blood Flow & Metabolism, 2009
- Kinetic modeling and fitting software for interconnected reaction schemes: VisKinAnalytical Biochemistry, 2007
- Optimization algorithms and weighting factors for analysis of dynamic PET studiesPhysics in Medicine & Biology, 2006
- Separable nonlinear least squares: the variable projection method and its applicationsInverse Problems, 2003
- Estimation of input function and kinetic parameters using simulated annealing: application in a flow modelIEEE Transactions on Nuclear Science, 2002
- Linear ridge regression with spatial constraint for generation of parametric images in dynamic positron emission tomography studiesIEEE Transactions on Nuclear Science, 2001
- Kinetic parameter estimation from attenuated SPECT projection measurementsIEEE Transactions on Nuclear Science, 1998
- An evaluation of the algorithms for determining local cerebral metabolic rates of glucose using positron emission tomography dynamic dataIEEE Transactions on Medical Imaging, 1995
- Elimination of Linear Parameters in Nonlinear RegressionTechnometrics, 1971