A Metal Nebulizer Capillary Electrophoresis/Fourier Transform Infrared Spectrometric Interface
Authors:
- 14 February 2003
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 75 (6) , 1393-1399
Abstract
A capillary electrophoretic (CE) system has been successfully interfaced to a Fourier transform infrared spectrometer. The advantage of such an interface is that analytes may be detected and often unequivocally identified without analyte derivatization. The interface consists of a stainless steel tube in which the CE capillary is placed and the two are held in contact with the use of a metal tee. A solvent elimination approach is used with the interface, so that analytes are deposited onto an infrared transparent window, that is, CaF2, and measured with the use of an infrared microscope. A critical component of this design is to provide an electrical connection at the end of the CE column to permit stable separations that allow for efficient transport of the sample onto the window. The interface produces an aerosol that is directed at the surface of the infrared transparent window. The use of a volatile electrolyte, along with the flow of helium, allows for partial evaporation of the electrolyte in flight and complete evaporation of the solvent and electrolyte on the surface of the window to produce a “dry”, or neat, analyte deposit.Keywords
This publication has 34 references indexed in Scilit:
- Coupling of Reversed-Phase Liquid Column Chromatography and Fourier Transform Infrared Spectrometry Using Postcolumn On-Line Extraction and Solvent EliminationAnalytical Chemistry, 1996
- Particle Beam LC/FT-IR Spectrometry Studies of Biopolymer Conformations in Reversed-Phase HPLC Separations: Native Globular ProteinsAnalytical Chemistry, 1996
- Conformational Effects on Reversed-Phase Chromatography of Proteins with Particle Beam LC/FT-IR Spectrometry and Free Solution Capillary ElectrophoresisAnalytical Chemistry, 1996
- Isomer and congener identification of chlorinated pyrenes by narrow-bore liquid chromatography—Fourier transform infrared spectrometryAnalytica Chimica Acta, 1994
- Use of Buffered Solvent Systems with Concentric Flow Nebulization Liquid Chromatography/Fourier Transform Infrared SpectrometryApplied Spectroscopy, 1993
- Electrospray micro liquid chromatography – Fourier transform infrared micro spectrometryJournal of High Resolution Chromatography, 1992
- Reversed-phase liquid chromatography/Fourier transform infrared spectrometry using concentric flow nebulizationAnalytical Chemistry, 1991
- Comparison of sampling techniques for combined supercritical fluid chromatography and Fourier-transform infrared spectrometry with mobile phase eliminationAnalytical Chemistry, 1989
- Interface of a reverse-phase high-performance liquid chromatograph with a diffuse reflectance Fourier transform infrared spectrometerAnalytical Chemistry, 1984
- A Practical Real-Time Fourier Transform Infrared Detector for Liquid ChromatographyApplied Spectroscopy, 1978