Encapsulation of Activated Carbon into a Hollow-Type Spherical Bacterial Cellulose Gel and Its Indole-Adsorption Ability Aimed at Kidney Failure Treatment
Open Access
- 11 November 2020
- journal article
- research article
- Published by MDPI AG in Pharmaceutics
- Vol. 12 (11) , 1076
Abstract
For reducing side effects and improvement of swallowing, we studied the encapsulation of activated carbon formulations with a hollow-type spherical bacterial cellulose (HSBC) gel using two kinds of encapsulating methods: Methods A and B. In Method A, the BC gelatinous membrane was biosynthesized using Komagataeibacter xylinus (K. xylinus) at the interface between the silicone oil and cell suspension containing activated carbon. In Method B, the bacterial cellulose (BC) gelatinous membrane was formed at the interface between the cell suspension attached to the alginate gel containing activated carbon and the silicone oil. After the BC gelatinous membrane was biosynthesized by K. xylnus, alginate gel was removed by soaking in a phosphate buffer. The activated carbon encapsulated these methods could neither pass through the BC gelatinous membrane of the HSBC gel nor leak from the interior cavity of the HSBC gel. The adsorption ability was evaluated using indole, which is a precursor of the uremic causative agent. From curve-fitting, the adsorption process followed the pseudo-first-order and intra-particle diffusion models, and the diffusion of the indole molecules at the surface of the encapsulated activated carbon within the HSBC gel was dominant at the initial stage of adsorption. It was observed that the adsorption of the encapsulated activated carbon by the intraparticle diffusion process became dominant with longer adsorption times.Keywords
This publication has 33 references indexed in Scilit:
- Uraemic syndrome of chronic kidney disease: altered remote sensing and signallingNature Reviews Nephrology, 2019
- A rare case of small bowel obstruction secondary to activated charcoal administrationJournal of Surgical Case Reports, 2019
- Review of the efficacy of AST-120 (KREMEZIN ® ) on renal function in chronic kidney disease patientsRenal Failure, 2019
- Chronic kidney disease as cause of cardiovascular morbidity and mortalityNephrology Dialysis Transplantation, 2005
- Small-Bowel Obstruction Secondary to Activated Charcoal and AdhesionsAnnals of Emergency Medicine, 1994
- Production of purified alginates suitable for use in immunoisolated transplantationApplied Microbiology and Biotechnology, 1994
- Charcoal stercolith with intestinal perforation in a patient treated for amitriptyline ingestionThe Journal of Emergency Medicine, 1994
- Prolonged survival of transplanted islets of Langerhans encapsulated in a biocompatible membraneBiochimica et Biophysica Acta (BBA) - Molecular Cell Research, 1984
- Preparation and drug adsorption characteristics of activated carbon beads suitable for oral administration.Chemical and Pharmaceutical Bulletin, 1984
- Microencapsulated Islets as Bioartificial Endocrine PancreasScience, 1980