Low cost wafer metrology using a NIR low coherence interferometry
Authors:
Open Access
- 30 May 2013
- journal article
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (11) , 13648-13655
Abstract
In this investigation, a low cost Si wafer metrology system based on low coherence interferometry using NIR light is proposed and verified. The whole system consists of two low coherence interferometric principles: low coherence scanning interferometry (LCSI) for measuring surface profiles and spectrally-resolved interferometry (SRI) to obtain the nominal optical thickness of the double-sided polished Si wafer. The combination of two techniques can reduce the measurement time and give adequate dimensional information of the Si wafer. The wavelength of the optical source is around 1 μm, for which transmission is non-zero for undoped silicon and can be also detected by a typical CCD camera. Because of the typical CCD camera, the whole system can be constructed inexpensively.Keywords
This publication has 9 references indexed in Scilit:
- Modified Roberts-Langenbeck test for measuring thickness and refractive index variation of silicon wafersOptics Express, 2012
- Development of a double sided stitching interferometer for wafer characterizationCIRP Annals, 2006
- Scanning wafer thickness and flatness interferometer2004
- Measurement of the influence of dispersion on white-light interferometryApplied Optics, 2004
- Silicon wafer thickness variation measurements using the National Institute of Standards and Technology infrared interferometerOptical Engineering, 2003
- Thickness-profile measurement of transparent thin-film layers by white-light scanning interferometryApplied Optics, 1999
- Three-dimensional imaging by sub-Nyquist sampling of white-light interferogramsOptics Letters, 1993
- Noncontact surface profiling using a novel capacitive technique: scanning capacitance microscopy1992
- A new stylus instrument with a wide dynamic range for use in surface metrologyPrecision Engineering, 1982