Removal of cerebrospinal fluid partial volume effects in quantitative magnetization transfer imaging using a three‐pool model with nonexchanging water component
- 13 November 2014
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 74 (5) , 1317-1326
Abstract
Purpose: Parameters of the two‐pool model describing magnetization transfer (MT) in macromolecule‐rich tissues may be significantly biased in partial volume (PV) voxels containing cerebrospinal fluid (CSF). The purpose of this study was to develop a quantitative MT (qMT) method that provides indices insensitive to CSF PV averaging.Theory and Methods: We propose a three‐pool MT model, in which PV macro‐compartment is modeled as an additional nonexchanging water pool. We demonstrate the feasibility of model parameter estimation from several MT‐weighted spoiled gradient echo datasets. We validated the three‐pool model in numerical, phantom, and in vivo studies.Results: PV averaging with the free water compartment reduces all qMT parameters, most significantly affecting macromolecular proton fraction (MPF) and cross‐relaxation rate. Monte‐Carlo simulations confirmed stability of the three‐pool model fit. Unlike the standard two‐pool model, the three‐pool model qMT parameters were not affected by PV averaging in simulations and phantom studies. The three‐pool model fit allowed CSF PV correction in brain PV voxels and resulted in good correlation with standard two‐pool model parameters in non‐PV voxels.Conclusion: Quantitative MT imaging based on a three‐pool model with a non‐exchanging water component yields a set of CSF‐insensitive qMT parameters, which may improve MPF‐based assessment of myelination in structures strongly affected by CSF PV averaging such as brain gray matter. Magn Reson Med 74:1317–1326, 2015.Keywords
Funding Information
- National Institute of Neurological Disorders and Stroke (R01-NS065034)
This publication has 44 references indexed in Scilit:
- Effect of cerebral spinal fluid suppression for diffusional kurtosis imagingJournal of Magnetic Resonance Imaging, 2012
- Quantitative MR imaging of two-pool magnetization transfer model parameters in myelin mutant shaking pupNeuroImage, 2012
- Prospective motion correction in brain imaging: A reviewMagnetic Resonance in Medicine, 2012
- Fast bound pool fraction imaging of the in vivo rat brain: Association with myelin content and validation in the C6 glioma modelNeuroImage, 2011
- MultiexponentialT2, magnetization transfer, and quantitative histology in white matter tracts of rat spinal cordMagnetic Resonance in Medicine, 2010
- Improved in vivo detection of cortical lesions in multiple sclerosis using double inversion recovery MR imaging at 3 TeslaEuropean Radiology, 2010
- Quantitative magnetization transfer measured pool‐size ratio reflects optic nerve myelin content in ex vivo miceMagnetic Resonance in Medicine, 2009
- Quantitative magnetization transfer imaging in postmortem multiple sclerosis brainJournal of Magnetic Resonance Imaging, 2007
- Iterative decomposition of water and fat with echo asymmetry and least‐squares estimation (IDEAL): Application with fast spin‐echo imagingMagnetic Resonance in Medicine, 2005
- Cerebrospinal fluid‐suppressed high‐resolution diffusion imaging of human brainMagnetic Resonance in Medicine, 1997