Real-Time 3D Fluoroscopy-Guided Large Core Needle Biopsy of Renal Masses: A Critical Early Evaluation According to the IDEAL Recommendations
- 6 August 2011
- journal article
- research article
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 35 (3) , 680-685
Abstract
Introduction Three-dimensional (3D) real-time fluoroscopy cone beam CT is a promising new technique for image-guided biopsy of solid tumors. We evaluated the technical feasibility, diagnostic accuracy, and complications of this technique for guidance of large-core needle biopsy in patients with suspicious renal masses. Methods Thirteen patients with 13 suspicious renal masses underwent large-core needle biopsy under 3D real-time fluoroscopy cone beam CT guidance. Imaging acquisition and subsequent 3D reconstruction was done by a mobile flat-panel detector (FD) C-arm system to plan the needle path. Large-core needle biopsies were taken by the interventional radiologist. Technical success, accuracy, and safety were evaluated according to the Innovation, Development, Exploration, Assessment, Long-term study (IDEAL) recommendations. Results Median tumor size was 2.6 (range, 1.0–14.0) cm. In ten (77%) patients, the histological diagnosis corresponded to the imaging findings: five were malignancies, five benign lesions. Technical feasibility was 77% (10/13); in three patients biopsy results were inconclusive. The lesion size of these three patients was <2.5 cm. One patient developed a minor complication. Median follow-up was 16.0 (range, 6.4–19.8) months. Conclusions 3D real-time fluoroscopy cone beam CT-guided biopsy of renal masses is feasible and safe. However, these first results suggest that diagnostic accuracy may be limited in patients with renal masses <2.5 cm.Keywords
This publication has 25 references indexed in Scilit:
- A new concept for non‐invasive renal tumour ablation using real‐time MRI‐guided radiation therapyBJU International, 2010
- C-Arm Cone Beam Computed Tomography Needle Path Overlay for Fluoroscopic Guided VertebroplastySpine, 2010
- A Critical Analysis of the Actual Role of Minimally Invasive Surgery and Active Surveillance for Kidney CancerEuropean Urology, 2010
- Biopsy of a renal mass: where are we now?Current Opinion in Urology, 2009
- No surgical innovation without evaluation: the IDEAL recommendationsThe Lancet, 2009
- The Clavien-Dindo Classification of Surgical ComplicationsAnnals of Surgery, 2009
- Accuracy of Percutaneous Core Biopsy in Management of Small Renal MassesUrology, 2009
- Contemporary Results of Percutaneous Biopsy of 100 Small Renal Masses: A Single Center ExperienceJournal of Urology, 2008
- Five‐year survival after surgical treatment for kidney cancerCancer, 2007
- Solid Renal Tumors: An Analysis of Pathological Features Related to Tumor SizeJournal of Urology, 2003