Continuous glucose monitoring: quality of hypoglycaemia detection
Authors:
- 13 September 2012
- journal article
- research article
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 15 (2) , 130-135
Abstract
Aims: To evaluate the accuracy of a (widely used) continuous glucose monitoring (CGM)‐system and its ability to detect hypoglycaemic events.Methods: A total of 18 patients with type 1 diabetes mellitus used continuous glucose monitoring (Guardian REAL‐Time CGMS) during two 9‐day in‐house periods. A hypoglycaemic threshold alarm alerted patients to sensor readings <70 mg/dl. Continuous glucose monitoring sensor readings were compared to laboratory reference measurements taken every 4 h and in case of a hypoglycaemic alarm.Results: A total of 2317 paired data points were evaluated. Overall, the mean absolute relative difference (MARD) was 16.7%. The percentage of data points in the clinically accurate or acceptable Clarke Error Grid zones A + B was 94.6%. In the hypoglycaemic range, accuracy worsened (MARD 38.8%) leading to a failure to detect more than half of the true hypoglycaemic events (sensitivity 37.5%). Furthermore, more than half of the alarms that warn patients for hypoglycaemia were false (false alert rate 53.3%). Above the low alert threshold, the sensor confirmed 2077 of 2182 reference values (specificity 95.2%).Conclusions: Patients using continuous glucose monitoring should be aware of its limitation to accurately detect hypoglycaemia.Keywords
This publication has 21 references indexed in Scilit:
- Measurement delay associated with the Guardian® RT continuous glucose monitoring systemDiabetic Medicine, 2010
- Effectiveness of Continuous Glucose Monitoring in a Clinical Care EnvironmentDiabetes Care, 2009
- Factors Predictive of Use and of Benefit From Continuous Glucose Monitoring in Type 1 DiabetesDiabetes Care, 2009
- Comparison of Accuracy and Safety of the SEVEN and the Navigator Continuous Glucose Monitoring SystemsDiabetes Technology & Therapeutics, 2009
- Comparison of the Numerical and Clinical Accuracy of Four Continuous Glucose MonitorsDiabetes Care, 2008
- Accuracy of the 5-Day FreeStyle Navigator Continuous Glucose Monitoring SystemDiabetes Care, 2007
- Defining and Reporting Hypoglycemia in DiabetesDiabetes Care, 2005
- Hypoglycemia Warning Signal and Glucose Sensors: Requirements and ConceptsDiabetes Technology & Therapeutics, 2003
- Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood GlucoseDiabetes Care, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986